Installation should only be done by qualified professionals with the
product turned
OFF
.
Instalation
Specification of the cables for proper installation:
▪ Power
connectors
(positive/negative)
........................................
▪ Remote connector
......................................................................
▪
Output signal connectors (speakers)
..........................................
▪ Fuses or circuit breakers
..............................................................
The use of a fuse or circuit breaker is mandatory to protect the system from short
circuits and overload. Install them as close to the battery as possible.
4 AWG
18 AWG
7 AWG
150A
Rádio / Player
STETSOM
GROUND
4 AWG
cable
POWER
4 AWG
cable
RECOMMENDED USE
OF AUXILIARY BATTERY.
REM
18 AWG
cable
REM (remote)
(maximum
12” of battery)
Fuse
150A
Battery