10
Spacing multi-row collector fields
1410002 Roof-tile bracket V2
..
..
..
1410009 Roof-tile bracket flat roof-tile
with lead 30 mm battens
Distance measures roof-tiles
Roof-tiles
roof covering
Initial position:
top edge
roof-tiles
Horizontal size FKA 240 H FKA 240 V FKA 270 H FKA 270 V
Measure A
212 cm
122 cm
239.3 cm
122 cm
Vertical size
Tolerance
FKA 240 H
+ / - 10 cm
FKA 240 V
+ / - 10 cm
FKA 270 H
+ / - 10 cm
FKA 270 V
+ / - 10cm
Measure H1
97 cm
187 cm
97 cm
214 cm
Measure H2
137 cm
227 cm
137 cm
254 cm
Measure H3
214 cm
394 cm
214 cm
448 cm
Measure H4
254 cm
434 cm
254 cm
488 cm
Measure H5
331 cm
601 cm
331 cm
682 cm
x
117 cm
207 cm
117 cm
234 cm
The next series is given by:
Hn = Hn - 2 + x
n is the number of the row of roof-tiles to be
calculated
example FKA 240 H
H6 = H6 - 2 + x
H6 = H4 + x (Height H4 see table)
H6 = 254 cm + 117 cm
H6 = 374 cm
For each collector row two rows roof-tiles are
necessary.
The vertical sizes H1 to Hn are each taken on
the top edge of the roof-tiles.
The measures for installation of the roof-tiles
are obligatory. Otherwise, the hydraulic collector
connection may be lying at the height of the
mounting profile, making it difficult to fasten the
collectors on the profile.
Initial position
If high snow loads are to be expected, the roof-
tiles have to be mounted above the rafters (in
other words the support must lie on the rafter /
alternatively, a higher number of roof-tiles may be
considered, depending on load).
Summary of Contents for FKA 240 Series
Page 1: ...1 Assembly Instructions Solar collectors FKA 240 270 Roof mounted installation...
Page 36: ...36 Initial operation 0 1 2 3 4 2 5 3 6 7 8 9 6 1 0 3 1 6 2 3 6 6 5 5...
Page 37: ...37 Initial operation Schematic drawing of the system construction and piping scheme...
Page 38: ...38 Initial operation Notes...