background image

 
SPECTRE nano 
UHF & Bluetooth

® 

reader 

Installation procedure 

 

 
SPECTRE nano 
Lecteur UHF & Bluetooth

®

 

Notice d’installation

 

 
SPECTRE nano 
Lector UHF y Bluetooth

®

 

Manual de instalación

 

 

 

© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1149X01 - Page 

5

 sur 

12 

-

 

Ed. 06/01/2022 

 

Bande de fréquence 

Références 

Bande de fréquence 

Références 

ETSI 
865 - 868 MHz 

 
 

SNA-R41-A-BT4-xx : TTL 
SNA-R42-A-BT4-5AB : RS232 

SNA-R43-A-BT4-7AB : RS485 
SNA-W43-A-BT4-7OS 

: OSDP™

 v1 & v2 

SNA-W42-A/BT4-5AX : SSCP

®

 v1 & v2- RS232 

SNA-W43-A/BT4-7AX : SSCP

®

 v1 & v2- RS485 

Maroc  
865.7 MHz 

 

SNA-R41-A-BT4-xx1M : TTL 
SNA-R42-A-BT4-5AB1M : RS232 

SNA-R43-A-BT4-7AB1M : RS485 
SNA-W43-A-BT4-7OS1M 

: OSDP™

 v1 & v2 

SNA-W42-A/BT4-5AX1M : SSCP

®

 v1 & v2- RS232 

SNA-W43-A/BT4-7AX1M : SSCP

®

 v1 & v2- RS485 

FCC 

902 - 928 MHz 
 

SNA-R51-A-BT4-xx : TTL 

SNA-R52-A-BT4-5AB : RS232 
SNA-R53-A-BT4-7AB : RS485 

SNA-W53-A-BT4-7OS 

: OSDP™

 v1 & v2 

SNA-W52-A/BT4-5AX : SSCP

®

 v1 & v2- RS232 

SNA-W53-A/BT4-7AX : SSCP

®

 v1 & v2- RS485 

 

 

Pérou 

916 - 928 MHz 
 

SNA-R51-A-U04-xx1PE : TTL 

SNA-R52-A-U04-5AB1PE : RS232 
SNA-R53-A-U04-7AB1PE : RS485 
SNA-W53-A-U04-7OS1PE 

: OSDP™

 v1 & v2 

SNA-W52-A/BT4-5AX1PE : SSCP

®

 v1 & v2- RS232 

SNA-W53-A/BT4-7AX1PE : SSCP

®

 v1 & v2- RS485 

Philippines 

918 - 920 MHz 

SNA-R51-A-U04-xx1PH : TTL 

SNA-R52-A-U04-5AB1PH : RS232 
SNA-R53-A-U04-7AB1PH : RS485 
SNA-W53-A-U04-7OS1PH 

: OSDP™

 v1 & v2 

SNA-W52-A/BT4-5AX1PH : SSCP

®

 v1 & v2- RS232 

SNA-W53-A/BT4-7AX1PH : SSCP

®

 v1 & v2- RS485 

Nouvelle-Zélande 
922 - 928 MHz 

SNA-R51-A-BT4-xx1NZ : TTL 
SNA-R52-A-BT4-5AB1NZ : RS232 

SNA-R53-A-BT4-7AB1NZ : RS485 
SNA-W53-A-BT4-7OS1NZ 

: OSDP™

 v1 & v2 

SNA-W52-A/BT4-5AX1NZ : SSCP

®

 v1 & v2- RS232 

SNA-W53-A/BT4-7AX1NZ : SSCP

®

 v1 & v2- RS485 

Australie 
920 - 926 MHz 

 

SNA-R51-A-BT4-xx1AU : TTL 
SNA-R52-A-BT4-5AB1AU : RS232 

SNA-R53-A-BT4-7AB1AU : RS485 
SNA-W53-A-BT4-7OS1AU 

: OSDP™

 v1 & v2 

SNA-W52-A/BT4-5AX1AU : SSCP

®

 v1 & v2- RS232 

SNA-W53-A/BT4-7AX1AU : SSCP

®

 v1 & v2- RS485 

 

Caractéristiques de l’alimentation

 

Utiliser une alimentation DC ES1, PS1 (selon IEC EN 62368-1) 

pour l’alimentation principale

.  

Alimentation principale : Typique : +12 Vdc  

Gamme +10 Vdc à +36 Vdc (utilisation en intérieur)       Gamme +10 Vdc à +30 Vdc (utilisation en extérieur) 

Consommation : 

     Typique : 0,9A sous +12 Vdc              Max : 1,25A sous +12 Vdc 

 

Caractéristiques 

Communication :  

RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data) 

Raccordement :

  

Borniers débrochables 1x8 points, Pas de 5 mm 

T° de fonctionnement : -30 °C / +60°C 
Indice de protection :  Boitier lecteur certifié IK10 - IP65 

Puce lue :   

EPC1 Gen2 (ISO 18000-63) - 1 à 62 octets max 

I/O : 

 

1 entrée et 1 sortie 

Buzzer :  

 

Activable / désactivable par logiciel et cavalier maître 

Relais : 

 

2A ; 24VDC  

1 LED : 

 

7 couleurs configurables (rouge, vert, bleu, orange, violet, turquoise, blanc) 

Anti-intrusion : 

Switch électro-méc Capteur de proximité infrarouge 

 

Type de câble préconisé 

RS485 : Utiliser du câble multiconducteur torsadé blindé par tresse, reliée à la masse du concentrateur. Déport max : 1000 m. à 9600 bauds 

 

RS232 : Déport max 15 m.  

 

  

Wiegand / Clock & Data : Utiliser du câble multiconducteur blindé non torsadé  

2 fils 6/10° - 30 m max 

4 fils 6/10° - 60 m max 

6 fils 6/10° - 100 m max 

2 fils 9/10° - 50 m max 

4 fils 9/10° - 100 m max 

 

 

Recommendations 

 

Installer le module à distance des câbles de transmission informatique ou d’origine de puissance (ex : RJ45, secteur...). 

 

 

Les perturbations qu’ils peuvent engendrer varie

nt en fonction de leur puissance de rayonnement et de leur proximité. 

 

Utiliser une alimentation filtrée et régulée. 

 

Un utilisateur ne doit pas se trouver de manière prolongée, à une distance inférieure à 34 cm d’une antenne conformément aux 

préconisations de la 

norme EN50364 applicable à ce type d’appareil.

 

 

Avant toute opération de service, vous devez mettre le lecteur hors tension

 

Dimensions (mm/in) 

 

 

 

US 

FR 

ES 

Summary of Contents for SPECTRE NANO

Page 1: ...Installation procedure Notice d installation Manual de Instalación ...

Page 2: ...232 SNA R53 A BT4 7AB1AU RS485 SNA W53 A BT4 7OS1AU OSDP v1 v2 SNA W52 A BT4 5AX1AU SSCP v1 v2 RS232 SNA W53 A BT4 7AX1AU SSCP v1 v2 RS485 Power Supply Characteristics Use an DC power supply ES1 PS1 as per IEC EN 62368 1 for main supply Main power supply Typical 12 Vdc Range 10 Vdc up to 36 Vdc indoor use Range 10 Vdc up to 30 Vdc outdoor use Consumption Typical 0 9A under 12 Vdc Max 1 25A under 1...

Page 3: ...rew the locking screw with Torx T8 tool without removing the screw from the plate so as not to lose the seal Step 3 Remove the metal mounting plate by exerting pressure on the metal plate while sliding it Leave the four mounting screws in place Wall Mounting To fix the reader to a wall with the metal mounting plate please follow the Steps 1 to 3 to remove the metal mounting plate from the reader T...

Page 4: ...al mounting plate from the reader Then follow the next steps Fix the standard 75x75 mm VESA type mounting bracket on the reader using the M4x12 stainless steel screws provided in the mounting kit Adjustable pole mounted kit KFX UHF 09 Adjustable wall mounted kit KFX UHF 08 TTL RS232 RS485 Connection J2 Type Wiegand Clock Data RS485 RS232 1 GND 2 Vcc 3 D0 DATA L TX 4 D1 CLOCK L RX 5 IN IN IN 6 OUT ...

Page 5: ...r initializing a few seconds then everything goes out The reader then waits for commands Coming from the factory the SPECTRE nano is compatible with SSCP v1 and v2 communication protocols You must use the Authenticate command to define the desired communication protocol All commands are available in the SSCP protocol specification Spec_Protocole_SSCP_UHF_ACCESS_V1 2_FR pdf Declaration of Complianc...

Page 6: ...A BT4 5AX1AU SSCP v1 v2 RS232 SNA W53 A BT4 7AX1AU SSCP v1 v2 RS485 Caractéristiques de l alimentation Utiliser une alimentation DC ES1 PS1 selon IEC EN 62368 1 pour l alimentation principale Alimentation principale Typique 12 Vdc Gamme 10 Vdc à 36 Vdc utilisation en intérieur Gamme 10 Vdc à 30 Vdc utilisation en extérieur Consommation Typique 0 9A sous 12 Vdc Max 1 25A sous 12 Vdc Caractéristique...

Page 7: ... vis de la plaque afin de ne pas perdre le joint d étanchéité Étape 3 Retirer la plaque de montage métallique en exerçant une pression sur la plaque métallique tout en la faisant glisser Laissez les quatre vis de montage en place Montage mural Si vous souhaitez fixer le lecteur au mur ou sur un boîtier d encastrement électrique avec la plaque de montage métallique suivre les étapes 1 à 3 permettan...

Page 8: ...mettant de retirer la plaque de montage métallique du lecteur Puis suivre les étapes suivantes Fixer le support de fixation de type VESA standard 75x75 mm sur le lecteur à l aide des vis M4x12 Inox fournies dans le kit de fixation Fixation mât orientable KFX UHF 09 Fixation murale orientable KFX UHF 08 Connexion TTL RS232 RS485 J2 Type Wiegand Clock Data RS485 RS232 1 GND 2 Vcc 3 D0 DATA L TX 4 D1...

Page 9: ...andes En sortie d usine le SPECTRE nano est compatible avec les protocoles de communication SSCP v1 et v2 Vous devez utiliser la commande Authenticate pour définir le protocole de communication souhaité Toutes les commandes sont disponibles dans la spécification du protocole SSCP Spec_Protocole_SSCP_UHF_ACCESS_V1 2_FR pdf Déclaration de conformité STid déclare que les lecteurs SNA R4x A SNA R5x A ...

Page 10: ...2 SNA W53 A BT4 7AX1AU SSCP v1 v2 RS485 Características de alimentación Utilizar una alimentación ES1 PS1 según IEC EN 62368 1 para el suministro principal Main power supply Típico 12 Vdc Rango 10 Vdc a 36 Vdc uso en interiores Rango 10 Vdc a 30 Vdc uso en exterior Consumo Típico 0 9A con 12 Vdc Max 1 25A con 12 Vdc Características Comunicación RS485 L L RS232 TD RD TTL Wiegand Clock Data Conexión...

Page 11: ...o con la herramienta Torx T8 sin quitar el tornillo de la placa para no perder el sello Etapa 3 Retire la placa de montaje de metal ejerciendo presión sobre la placa de metal mientras la desliza Deje los cuatro tornillos de montaje en su lugar Mural de montaje Si desea montar el lector en la pared o en una caja posterior eléctrica con la placa de montaje de metal siga las etapas 1 a 3 para quitar ...

Page 12: ... quitar la placa de montaje de metal del lector Luego siga los siguientes pasos Fije el soporte de montaje estándar de 75x75 mm tipo VESA en el lector con los tornillos de acero inoxidable M4x12 incluidos en el kit de fijación Fijación mástil orientable KFX UHF 09 Fijación mural orientable KFX UHF 08 TTL RS232 RS485 conexión J2 Type Wiegand Clock Data RS485 RS232 1 GND 2 Vcc 3 D0 DATA L TX 4 D1 CL...

Page 13: ...tá encendido el LED blanco y el timbre se encienden Lector inicializándose unos segundos luego todo se apaga Luego el lector espera los comandos Al salir de fábrica el SPECTRE nano es compatible con los protocolos de comunicación SSCP v1 y v2 Debe utilizar el comando Autenticar para configurar el protocolo de comunicación deseado Todos los comandos están disponibles en la especificación del protoc...

Reviews: