4. Settings
4.1 Temperature
Appliance type with external temperature selector
The temperature can be variably adjusted. In the delivered con-
dition, temperature selection is limited. This limitation can be
cancelled by a qualified contractor (see chapter "Installation /
Settings").
You can interrupt the heating process by setting the temperature
selector to "cold".
26
�02
�7
9�
002
7
• Cold
I Low temperature setting, 35 °C
II Recommended setting for energy saving,
low scaling, 60 °C
III Maximum temperature setting, 85 °C
Depending upon the system, the temperatures may vary from
the set value.
Appliance type with temperature selector inside the control
panel
The temperature can be freely selected by the qualified contractor
(see chapter "Installation / Settings").
Factory setting: 60 °C
4.2 Rapid heating during dual circuit operation
For appliance types with dual circuit operation, the heating con-
tractor can install a pushbutton to control the rapid heat-up func-
tion remotely. If required, you can switch this on. The rapid heat-
up function switches off when the selected temperature has been
reached and will not switch on again.
5. Cleaning, care and maintenance
f
f
Have the electrical safety of the appliance regularly checked
by an electrician.
Scaling
f
f
Almost every type of water will deposit lime at high tempera-
tures. Limescale will settle inside the appliance and affect its
function and service life. The heating elements must there-
fore be descaled from time to time. A qualified contractor
who is aware of the local water quality will tell you when the
next service is due.
f
f
Check the taps/valves regularly. You can remove limescale
deposits at the tap outlets using commercially available des-
caling agents.
f
f
Regularly activate the safety valve to prevent it from becom-
ing blocked e.g. by limescale deposits.
6. Troubleshooting
Fault
Cause
Remedy
The water does not heat
up.
There is no power.
Check the fuses/MCBs in
your fuse box.
The temperature is incor-
rectly adjusted.
Check the temperature
setting.
The flow rate is low.
The aerator in the taps or
shower heads is dirty or
scaled-up.
Clean or descale the
aerator or shower head.
Water drips from the
safety assembly after
heating has stopped.
The valve seat is con-
taminated.
Depressurise and isolate
the appliance from the
power supply. Request
your qualified contractor
to attend.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):