_,:
:::67,(%(/(/7521&20
,167$//$7,21
6$)(7<
7. Safety
Only qualified contractors should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
7.2
Instructions, standards and regulations
Note!
Observe all applicable national and regional
regulations and instructions.
Note!
When installing the appliance in rooms with a bath
and/or shower, take the relevant safety zone into
account in accordance with the information on the
appliance type plate.
8. Equipment
description
8.1 Standard
delivery
— Screws
— Rawl plugs
— Cable entry
— Cap (2x)
9. Installation
9.1 Installation
information
— Wood ceilings may become hot even if the minimum
clearances are observed. Dark spots or fine shrinkage cracks
on wooden ceilings therefore cannot be ruled out.
— Never install the appliance directly below a socket.
9.2
Installation conditions and preparations
— Only install the appliance in a fixed position, horizontally on
the wall. Never install the appliance on the ceiling.
— Install the appliance with the pull cord at the bottom. The
appliance can only be pivoted downwards.
— Always maintain the specified minimum clearances. Install
the appliance so that the pull cord cannot be reached from the
shower or the bath.
Injury warning!
Install the appliance out of the reach of children.
Power cable
Below plaster:
The connection must be in the area of the mounting panel.
Above plaster:
»
Feed the electrical power cable into the mounting panel via the
cable grommet.
If installation conduit projects 3.5 to 4 cm into the mounting panel,
the cable grommet is not required.
9.3 Power
supply
»
Observe the minimum size of the power cable, which can be
found in the chapter Specification.
Risk of electrocution!
Make the connection to the mains power supply
only as a permanent connection (the appliance has
no strain relief). The appliance must be able to be
separated from the mains power supply by an
isolator that disconnects all poles with at least 3 mm
contact separation.
Ensure that the appliance can be earthed!
Note!
Observe the type plate. The specified voltage must
match the mains voltage.
10. Installation
10.1 Installation
Risk of electrocution!
Carry out all electrical connection and installation
work in accordance with relevant regulations.
10.1.1 Appliance installation
»
Remove the polyst yrene inser ted into the grille as
transport protection.
2
6
_0
7
_3
1
_0
1
0
1
»
Undo both screws on the pivot hinge of the mounting panel.