instALLAtion
safety
10
| LWF FBF 160 www.stiebel-eltron.com
instALLAtion
6. Safety
Only qualified contractors should carry out installation, commis-
sioning, maintenance and repairs.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the product
are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
7. Product description
Standard delivery
The following are delivered with the product:
- Filter cassette M5
- 2 Filter frame
- 2 star grip screws for securing the cover
Accessories
- Insulation mats ZLWF FBF 160 ISO
8. Preparation
8.1 Installation location
≥400
D
00000
46
28
5
Ensure that there is sufficient space for changing filters and clean-
ing the filter box.
9. Installation
Material losses
We recommend not fitting the filter box with the cover
facing downwards.
Locking tabs should prevent the filter frames from slip-
ping out. The pressure from contact with the filter should
hold the filter frame in place below the locking tabs. With
thin filters or if a filter frame is inserted in the filter box
without a filter, the filter frames may fall out when the
cover is removed.
If you can only fit the filter box with the cover facing
downwards, you must stop the filter frames from falling
out when removing the cover.
If you fit the filter box with the cover facing downwards,
do not use fleece filters. These filters are thin. The filter
frame would fall out.
Note
Pay attention to the air flow direction indicated on the
product.
D
00000
36
95
0
f
f
Undo the star grip screw by hand.
f
f
Remove the cover.
D
00000
74
89
6
1
1 Direction of flow
f
f
When fitting the filter box, observe the direction of flow.
f
f
Connect the air ducts tightly (airtight) to the filter box.