INSTALLATION
Installation
28
| LWE 40
www.stiebel-eltron.com
D
00000
700
37
f
f
To prevent contaminating the wall mount casing during plas-
tering, use the cover included in the standard delivery.
5.1.2 Installation version 2: Fixing the wall mount casing with
PUR foam
D
00000
700
33
1
1
1
1
1 Fixing holes
f
f
Seal the fixing holes with the plugs included in the standard
delivery.
f
f
Align the wall mount casing horizontally.
D
00000
700
37
f
f
To prevent contaminating the wall mount casing during plas-
tering, use the cover included in the standard delivery.
D
00000
700
72
1
1
1 Aperture for injecting PUR foam for fixing the wall mount
casing
Material losses
Only use rigid 2-component PUR foam.
f
f
To secure the wall mount casing in position, spray a little
PUR foam through the plaster protection cover into the cavity
between the wall mount casing and the wall at two opposite
corners.
f
f
Hold the wall mount casing in place until the foam has dried
and the wall mount casing is held securely in position.
5.1.3 Foaming
Material losses
Make sure that the support elements are correctly posi-
tioned in the wall mount casing.
Material losses
Only use rigid 2-component PUR foam.
Note
Observe the instructions for the PUR foam. To increase
the foam volume, you may need to moisten the substrate.
Inside
D
00000
700
34
1
1
1
1
1
1
1 Apertures for foaming
The plaster protection cover has six apertures for foaming.