iNSTallaTiON
Specification
22
| HSBB 200 S (GB) www.stiebel-eltron.com
16.4 Details on energy consumption
Product datasheet: DHW cylinder to regulation (EU) no. 812/2013
HSBB 200 S (GB) set
236916
Manufacturer
STIEBEL ELTRON
Supplier’s model identifier
HSBB 200 S (GB) Set
Energy efficiency class
B
Standby losses
W
55
Cylinder capacity
l
191
16.5 Data table
HSBB 200 S (GB) set
236916
Hydraulic data
Nominal capacity, DHW cylinder
l
181
Surface, indirect coil
m²
1.6
External available pressure differential at 1.0 m³/h
hPa
666
External available pressure differential at 1.5 m³/h
hPa
560
External available pressure differential at 2 m³/h
hPa
274
Hot water volume > 40°C
l
152.7
Primary heating water input power at flow rate, upper indirect coil
kW - l/min
21.0 / 15.6
Pressure drop at 1.0 m³/h, indirect coil, top
hPa
8
Reheating time, upper indirect coil
min
22.6
Max. operating temperature heating water
°C
89
Application limits
Max. permissible pressure (Design Pressure) DHW cylinder
MPa
0.7
Test pressure, DHW cylinder
MPa
1.5
Max. permissible pressure (Design Pressure), upper indirect coil
MPa
0.3
Max. throughput
l/min
25
Maximum permissible pressure
°C
89
Heating water quality requirements
Water hardness
°dH
≤3
pH value (with aluminium compounds)
8.0-8.5
pH value (without aluminium compounds)
8.0-10.0
Conductivity (softening)
μS/cm
<1000
Conductivity (desalinating)
μS/cm
20-100
Chloride
mg/l
<30
Oxygen 8-12 weeks after filling (softening)
mg/l
<0.02
Oxygen 8-12 weeks after filling (desalinating)
mg/l
<0.1
Power consumption
Power consumption, emergency/booster heater
kW
5.9
Max. power consumption, circulation pump, heating side
W
60
Energy data
Standby energy consumption/24 h at 65 °C
kWh
1.3
Energy efficiency class
B
Electrical details
Rated control voltage
V
230
Control circuit fuse
A
1 x B 16
Rated voltage, emergency/booster heater
V
230
Emergency/booster heater fuse
A
2 x B 16
Frequency
Hz
50