13.3 Changing the fuse
Changing the fuse
26
�0
7�
27
�0
36
0
Fine fuse 5x20 mm 2A (slow)
As additional protection, there is a replaceable fuse for
the electronic charge controller in the switching circuit.
This fuse is located in a two-part fuse holder, positioned between
mains terminals X1 and X2.
To change the fuse, pull the upper part with the fuse out of the
lower part.
Danger of electrocution!
Isolate the appliance from the power supply before
changing the fuse.
13.4 Symbols on the type plate
000000 0000 000000
Type plate example
26
�0
7�
27
�0
35
5
Symbols on the type plate (example ETW 120)
Total weight
Charging
Discharge
Booster heater
Fan
14. Maintenance
The fan duct behind the air outlet grille should be checked
by a contractor every two years. Small dirt deposits can build
up here.
As part of regular maintenance, we recommend also checking the
control components. The safety and control components, and the
entire charge and discharge control system should be checked by
a contractor no more than ten years after commissioning.