background image

1

IP

 

35 EC / 45 EC / 60 EC

English

Instantaneous shower water heater - Operation and installation instructions

This water heater must be installed (water and electrical installation), commissioned and serviced by approved 

service technicians in accordance with these instructions.

22 Jun 2009

Summary of Contents for IP 35 EC

Page 1: ...ous shower water heater Operation and installation instructions This water heater must be installed water and electrical installation commissioned and serviced by approved service technicians in accordance with these instructions 22 Jun 2009 ...

Page 2: ...2 4 5 3 8 6 7 a b c e f d Fig 1 Fig 2 Fig 4 Fig 3 Fig 5 1 2 Beware the cable connector inside ...

Page 3: ...1 12 13 14 16 15 17 18 19 20 9 23 24 25 Flow Sw A B C L N D E F G A Heating Element B Smart Pump Control PCB C ELCB D Triac Set E Thermal cut out F Smart Pump Front PCB G Booster Pump 220 240 V AC ONLY Fig 6 Fig 8 Fig 7 Fig 9 ...

Page 4: ...hat is needed for cleaning of the housing is a damp cloth Do not use any abrasive cleaning agents or agent containing solvents Maintenance work may only be carriedoutbyaqualifiedtechnician 1 5 Hot water capacity The hot water capacity depends on the power of the unit the cold water temperature and the flow volume 1 6 Regulations and Provisions Regulations of the local power supply company should b...

Page 5: ...onnection cable through the cable seal in the rear wall Guide the unit over the wall securing screws and slide it downwards 8 Fig 5 7 Fit the cold water connection Connect the water valve 24 Fig 9 with the filter 22 Fig 9 and the washer 23 Fig 9 to the cold water inlet of the unit 19 Fig 6 Tighten the union nut and washer 25 Fig 9 to the water valve 8 Straighten the unit and tighten the screws 9 C...

Page 6: ...zards water temperature too high Hand over this instruction manual to the user and to be kept on a safe place for future reference Service note When carrying out any work isolate the unit from the mains and shut off the water connection Clean the filter Fig 9 Disconnect water valve 24 remove filter 22 and clean Re assemble in reverse order ELCB Function Before using this unit switch on the electri...

Page 7: ...s 4 Fault elimination for the user Fault The unit is not turning ON The Reset Button E drop The unit shutdown by itself Cause The minimum required flow rate or water pressure is too low Possible Earth leakage Safety thermostat cut off Rectification Check the shower head for dirt and limescale to unclog the water flow Turn the water flow to maximum Increase mains pressure Consult with qualified tec...

Page 8: ...SIZE A5 MATERIAL WHITE PAPER 80 G Part no 7901 281808 Rev 00 ...