EN
G
L
IS
H
WWW.STIEBEL-ELTRON.COM LWA
252
|
LWA 252 SOL |
17
INSTALLATION
INSTALLATION
The discharge air connector is located at the top of the equipment
as standard. The following steps are necessary for conversion:
»
Isolate the appliance from the power supply by pulling the power
plug.
2
6
_0
4
_0
1
_0
44
3
»
Removing the cover from the top of the appliance.
»
Undo the 6 self-tapping screws from the r.h. upper side panel.
»
Tip the side panel approx. 10 degrees to the side and remove
the EPS profile that faces to the front of the appliance upwards.
»
Pull the second EPS profile about 20 mm in the direction of the
appliance front and then remove it upwards by tipping the side
panel by approx. 10 degrees.
»
Remove the cover panel from the side panel.
»
Remove the discharge air connector from the appliance cover.
»
Fit the cover panel to the appliance cover.
»
Fit the discharge air connector from the inside to the side panel.
»
Install the EPS profiles in reverse order, so that the airway now
points towards the appliance side panel.
»
Secure the r.h. top side panel with 6 self-tapping screws.
»
Fit the appliance cover with 4 self-tapping screws.
For anti-vibration separation and service reasons, connect the
LWA to extract and discharge air ducts with about 1 m length of
flexible pipe each.
Also insulate these lines.
!
Risk of damage
When operating a dryer or a cooker hood that extracts
air, ensure also, that a sufficiently large air flow rate
is supplied to that equipment, independent of the
ventilation equipment.
10.6 Power
supply
The appliance is supplied fully wired, and should be plugged into
an accessible earthed mains power socket.
Danger of electrocution!
Isolate the appliance from the power supply by pulling
the power plug prior to commencing work on the
control panel.
Only qualified electricians must carry out the connection work.
Route power supply and control cables separately.
Observe VDE 0100 [or local regulations] and the regulations of your
local power supply utility.
The terminals are located beneath the lower front fascia, top right
hand side. When removing the front fascia ensure that the earth
cable is not ripped off the front fascia. If necessary, remove the
cable from the blade terminal.
2
6
_0
4
_0
1
_0
44
6
14
13
4
3
2
1
PE
X1
5
6
7
L
8
N
9
10
11
12
N
L
Solarkreis-
pumpe