INSTALLATION
MAINTENANCE, CLEANING AND SAFETY EQUIPMENT
2
6
_0
4
_0
1
_0
44
5
Protective motor switch
The protective motor switch will shut down the compressor if
it is overloaded because of excessive thermal load. Remove the
relevant fault. After a short while, the protective motor switch will
restart the compressor automatically.
Protective anode
Two protective anodes are integrated into the cylinder to protect
it against corrosion.
The protective anodes are pushed through the flange from
inside outwards and secured. For inspections, the flange will be
removed to enable the simultaneous inspection of the electrode,
the immersion heater and the internal enamel coating. When
replacing the anode, ensure a perfect contact with a metallic,
conductive surface during assembly.
The timing of the inspection is subject to the local water quality
and is determined by your local contractor.
13.3.2 System safety equipment
Safety valve (on-site provision)
This valve opens when the water pressure exceeds the preset
value of 6 bar, thereby relieving the pressure. It is adjusted so that
no water will be expelled when heating is switched OFF. Should
it continue to drip excessively, either the valve seat has become
contaminated, the water pressure is too high or the pressure
reducing valve has become faulty.
Pressure reducing valve (on-site provision)
Check the valve for perfect function. Replace it, if required.