LWZ 304-404 SOL |
21
INSTALLATION
Installation
5.9.2 Cable routing
f
f
Push all connecting cables and sensor leads through one of
the cable entries located at the top of the back panel of the
cylinder module.
5.9.3 Terminals X3: Heat pump (compressor) and electric
emergency/booster heater
D
00000
53
52
8
WP
Heat pump (compressor)
PE, L1, L2, L3, N
MFG
Electric emergency/booster heater of
the multi function assembly
PE, L1, L2, L3, N
For optimum function, connect all three stages of the electric
emergency/booster heater.
5.9.4 Terminal X4
Note
Install additional contactor relays if more than one exter-
nal heating circuit pump will be connected at the heating
circuit 2 pump terminal "P-HK2". Use our relay box (see
chapter "Appliance description / Further accessories").
D
00000
38
97
0
Steuerung
Control
PE, L1, N
HMV
Mixer
N, CLOS, OPEN
P-HK2
Heating circuit 2 pump
PE, N, L
EVU
Contact for Power-OFF command by
the power supply utility (option)
KUE
Cooling (option)
L, N
O/K
Oven / fireplace (option)
L, L'
P-S
Solar circuit pump (option)
L, N
SL
Quick-acting air vent valve (option)
L, L'
FA
Window open (option)
L, N
The SL terminal is a 230 V input for activating ventilation by means
of a pushbutton.
The FA terminal is a 230 V output for switching an automatically
controlled window with passive cooling, for example.
The KUE is a 230 V output for activating the cooling circuits.
5.9.5 Power-OFF
Connect the signal from the power time switch to the X4/power
supply terminal (see chapter "Commissioning / Power-OFF").
5.9.6 Special tariff
Note
For special tariff connections, ensure that terminal X4/L1
(extractor fan) is always 'live'.
5.9.7 Connecting internal cables/leads
The cylinder temperature sensor and the power cable for the sig-
nal anode are routed out of the function module at the top l.h.
side. All cables/leads are identified accordingly.
1
2
3
26
0
4
01
0
56
1
1 Anode connection at the cylinder
2 Terminal bracket X24
3 Earth block X32
f
f
Connect the signal anode at the top of the cylinder. Route
the anode cable through the groove cut into the thermal
insulation.
f
f
Connect the cable from the terminal bracket X24 to the earth
block X32.