15.2 Wiring diagram
3/PE ~ 380 - 400 V
85
�02
�02
�0
002
1 Heating
2 High limit safety cut-out
3 Safety pressure limiter
Priority control with LR 1-A
85
�0
2�
02
�0
00
3�
2
1
1 Control cable to the contactor of the 2nd appliance (e.g. elec-
tric storage heater).
2 Control contact drops out when switching the instantaneous
water heater on.
15.3 DHW output
The DHW output is subject to the mains voltage, the appliance's
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate (see
chapter "Troubleshooting").
Connected load in
kW
38 °C DHW output in l/min.
Rated voltage
Cold water inlet temperature
380 V
400 V
5 °C
10 °C
15 °C
20 °C
9.6
4.2
4.9
6.0
7.6
12.9
5.6
6.6
8.0
10.2
15.2
6.6
7.8
9.4
12.1
17.1
7.4
8.7
10.6
13.6
10.6
4.6
5.4
6.6
8.4
14.3
6.2
7.3
8.9
11.3
16.8
7.3
8.6
10.4
13.3
19
8.2
9.7
11.8
15.1
12.2
5.3
6.2
7.6
9.7
16.3
7.1
8.3
10.1
12.9
19
8.2
9.7
11.8
15.1
21.7
9.4
11.1
13.5
17.2
13.5
5.8
6.9
8.4
10.7
18
7.8
9.2
11.2
14.3
21
9.1
10.7
13.0
16.7
24
10.4
12.2
14.9
19.0
Connected load in
kW
50 °C DHW output in l/min.
Rated voltage
Cold water inlet temperature
380 V
400 V
5 °C
10 °C
15 °C
20 °C
9.6
3.0
3.4
3.9
4.6
12.9
4.1
4.6
5.3
6.1
15.2
4.8
5.4
6.2
7.2
17.1
5.4
6.1
7.0
8.1
10.6
3.4
3.8
4.3
5.0
14.3
4.5
5.1
5.8
6.8
16.8
5.3
6.0
6.9
8.0
19
6.0
6.8
7.8
9.0
12.2
3.9
4.4
5.0
5.8
16.3
5.2
5.8
6.7
7.8
19
6.0
6.8
7.8
9.0
21.7
6.9
7.8
8.9
10.3
13.5
4.3
4.8
5.5
6.4
18
5.7
6.4
7.3
8.6
21
6.7
7.5
8.6
10.0
24
7.6
8.6
9.8
11.4
15.4 Application areas / Conversion table
Specific electrical resistivity and specific electrical conductivity
(see chapter "Data table").
Standard specifica-
tion at 15 °C
20 °C
25 °C
Resistivi-
ty ρ ≥
Conductivity
σ
≤
Resistivi-
ty ρ ≥
Conductivity
σ
≤
Resistivi-
ty ρ ≥
Conductivity
σ
≤
Ωcm mS/m μS/cm
Ωcm mS/m μS/cm
Ωcm mS/m μS/cm
900
111
1111
800
125 1250
735
136 1361