background image

iNSTallaTiON 

 

Safety

www.stiebel-eltron.com 

SNE 5 t ECO GB| 

9

iNSTallaTiON

7.  Safety

Only a qualified contractor should carry out installation, commis-

sioning, maintenance and repair of the appliance.

7.1  General safety instructions

We guarantee trouble-free function and operational reliability only 

if original accessories and spare parts intended for the appliance 

are used.

7.2  Instructions, standards and regulations

 

Note

Observe all applicable national and regional regulations 

and instructions.

8.  Appliance description

The open vented (non-pressurised) appliance is only suitable 

for undersink installation. The appliance is intended to heat cold 

water for supplying a single draw-off point.
The appliance must only be installed with an open (non-pres-

surised) tap (see chapter "Installation / Appliance description / 

Accessories").

8.1  Standard delivery

The following are delivered with the appliance:

 

- Wall mounting bracket

8.2  Accessories

8.2.1  Required accessories

The following taps are available as accessories for open vented 

operation: 

Mixer taps

 

- WST, WUT

Mono-lever mixer taps

 

- MEW, MES, MEWC

Sensor taps

 

- WSN

8.2.2  Additional accessories

 

- Strainer for the "cold water inlet" connection

9.  Preparation

f

f

Flush the water line thoroughly.

Water installation

No safety valve is required.

Taps/valves

!

 

Material losses

Sealed unvented taps are not permitted.

f

f

Install a tap for open vented operation.

9.1  Installation site

!

 

Material losses

Install the appliance in a room free from the risk of frost.

!

 

Material losses

Mount the appliance on the wall. The wall must have 

sufficient load bearing capacity.

!

 

Material losses

The appliance is only suitable for undersink installation. 

The water connections of the appliance are at the top.

 

Note

Make sure that the appliance is freely accessible for main-

tenance work.

Always install the appliance vertically and near the draw-off point.

820

520-570

D

00000

71

78

7

850

550-600

D

00000

71

78

8

Summary of Contents for SNE 5 t ECO

Page 1: ...OPERATION AND INSTALLATION Open vented non pressurised small water heater SNE 5 t ECO GB...

Page 2: ...stallation Maintenance Draining the appliance SPECIAL INFORMATION OPERATION 1 General information 3 1 1 Safety instructions 3 1 2 Other symbols in this documentation 3 1 3 Units of measurement 3 2 Sa...

Page 3: ...njury or death CAUTION Failure to observe this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent sym...

Page 4: ...content at the set temperature in line with the pre selected oper ating mode The appliance may only be installed with taps for open vented non pressurised water heaters see chapter Installation Appli...

Page 5: ...lation Troubleshooting Fault list Call your qualified contractor Green LED flashes The appliance was disconnected from the power sup ply for a long time approx 8 hours Reset the day and time 3 1 3 Dis...

Page 6: ...symbol appears you can change the setting of the menu item with and Press OK to save the setting To exit the standard menu press Menu The standard display appears Note During initial start up and fol...

Page 7: ...d weekly To configure a comfort phase in time program Pro3 proceed as follows f f In the configuration menu use and to call up time program Pro3 f f Press OK The display shows 3 f f Press OK The day o...

Page 8: ...s Activating parameter P5 resets the appliance to the factory setting 5 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the ap...

Page 9: ...INSTALLATION TEMPLATE...

Page 10: ......

Page 11: ...79 mm 140 mm 407mm 263mm 407mm 263mm D0000071802...

Page 12: ...NOTES...

Page 13: ...wing are delivered with the appliance Wall mounting bracket 8 2 Accessories 8 2 1 Required accessories The following taps are available as accessories for open vented operation Mixer taps WST WUT Mono...

Page 14: ...with a fully opened tap see chapter Installation Specification Data table Match up the colour coding on the tap water connections and the appliance R h side blue Cold water inlet L h side red DHW outl...

Page 15: ...iance carries out a new boil dry protection check f f If the fault continues to be displayed reset the appliance P5 on 11 1 1 Appliance handover f f Explain the functions of the appliance to the user...

Page 16: ...replace the strainer 14 3 Opening the appliance Material losses Incorrect handling can damage the BUS connection be tween the programming unit and the main PCB f f Carefully pivot the appliance cover...

Page 17: ...e power cable The power cable must only be replaced by a qualified contractor with an original spare part D0000071890 f f Route the power cable along the cable guide 14 7 Positioning the temperature s...

Page 18: ...Energy conversion efficiency 38 Annual power consumption kWh 489 Default temperature setting C 55 Sound power level dB A 15 Daily power consumption kWh 2 260 15 7 Data table SNE 5 t ECO GB 202135 Hydr...

Page 19: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Page 20: ...Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387...

Reviews: