INSTALLATION
INSTALLATION INSTRUCTIONS FOR THE LICENSED INSTALLER
5. Installation instructions for the
licensed installer
!
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be
done by qualifi ed person(s) in accordance with all
applicable codes and standards, including fi re-rated
construction.
b) When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden utili-
ties.
DANGER Electrocution
Before proceeding with any installation,
adjustment, alteration, or service of this unit all
circuit breakers and disconnect switches servicing
the unit must be turned off. Failure to do so could
result in serious personal injury or death.
WARNING Electrocution
Do not install unit where it can accidentally
be splashed with water, failure to do so could result
in serious personal injury or death.
All electrical work must comply with national
and applicable state and local electrical codes.
The circuit should be equipped with a “ground fault
interrupter” where required by local, state or national
electrical codes.
The Ultronic hand dryer must have its own inde-
pendent circuit using cable of the appropriate size
protected by a correctly rated circuit breaker. The
Ultronic 1 S/W units are designed for 110-120 Volt
electrical service and require a 15 amp circuit break-
er and a #14 gauge copper wire. The Ultronic 2 S/W
units are designed for 220-240 V or 208 V electrical
service and require a 15 amp circuit breaker and a
#14 gauge copper wire.
6. Minimum
clearances
WARNING Electrocution
Do not install unit where it can accidentally
be splashed with water. Observe all minimum
clearance requirements. Failure to do so could result
in serious personal injury or death.
Do not install the hand dryer in DANGER ZONES 0, 1,
or 2 (see upper right diagram). Doing so may allow
the unit to be splashed with water which could
result in serious personal injury or death.
24”
(600
mm
)
24”
(600
mm
)
89”
118”
(3000
mm
)
(2250
mm
)
1
2
3
0
26
_0
7_
31
_0
16
7
0
DANGER ZONE: do not install unit in bathtubs
showers, or wash basins.
1
DANGER ZONE: do not install directly above bathtubs
or showers.
2
DANGER ZONE: do not install within 24˝ of bathtubs
or showers
3
SAFE AREA: unit must be installed in this area,
outside of DANGER ZONES 2, 1 and 0.
5.1”
(1
30 mm
)
12”
(
PP
)
´
(
127 mm
)
1.6”
(
40 mm
)
D00000
20
79
8
Before mounting the unit to the wall, ensure
all minimum distances are met for safety and
performance considerations.