background image

 INSTRUCTION  MANUAL  VIGIBELT

®

 TOUCH ATEX (II 2 D) 

GB

 

– 

1/4 

www.stifnet.com

 - VER. 01/16 - N° DOC BE0455041

 

 
 

FUNCTION 

 
-  The VIGIBELT

®

 TOUCH is a lateral movement sensor that detects run-out of elevator belts or conveyor belts, and 

at the same time the run-out of the lift pulley. It reacts to the pressure of the belt coming into contact with the front 
face of the sensor. Baffle plates are usually fitted opposite each other, preferably on the upward leg close to the 
pulleys for elevators, and on the load bearing side close to the drums for conveyors. 

The sensors can be connected directly to a PLC,  or for absolutely safety, to an  independent "monitoring M-

JET” 

central unit. The electrical circuit can control an alarm or a machine shut down. 

For elevators more than 20 meters long, we recommend fitting the head with a second VIGIBELT

®

 TOUCH kit, still 

on the upward leg.

 

The sensors trigger when the belt applies a force of approximately 5 daN.

 

 
 

DESCRIPTION 

 
-  The VIGIBELT

®

 TOUCH kit comprises two sensors, four elastomer spacers (3mm NBR) and the fastenings (M6). 

  

Composition : 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PRECAUTIONS 

 
The VIGIBELT

®

 TOUCH must be installed, connected and put into service by competent personnel. The personnel 

should be qualified electricians and know the regulations and requirements concerning the installation of these 
appliances, especially when installed in ATEX areas. 

-  Carry out a study prior to the electrical connection of the VIGIBELT

®

 TOUCH sensors (standardised electrical 

diagram, PLC control, electricity supply and protection). 

-  Define the sensing distance between the belt and the elevator shaft (confirmation of the triggering distance by the 

person in charge of the site). 

-  Before  any  installation  or  intervention  on  the  VIGIBELT

®

  TOUCH,  it  is  essential  to  make  sure  that  the  bucket 

elevator is shut down (intervention warning to be posted on the machine). 

-  When the VIGIBELT

®

 TOUCH is dismantled, the user should ensure that the appliance is scrapped properly and 

that the components are passed to the appropriate specialist collection centres according to their nature (stainless 
steel, electrical equipment, seals, etc.). 

 

 

 

 

 

 

Z.A. de la lande - 49170 Saint-Georges-sur-Loire - France 

Siège social,  achats et usine : 

 tél.: +33 2 41 72 16 80 - Fax +33 2 41 72 16 85 

Service commercial France Export : 

 tél.: +33 2 41 72 16 82 - Fax +33 2 41 39 32 12 

Email :

 

sales@stifnet.com

 

- Site internet :

 

www.stifnet.com

 

SAS au capital de  800 000 € - R.C.S. Angers B 328 876 503 - 84B12 APE 2511Z - N° TVA FR 35 328 876 503 

2x VIGIBELT

®

 TOUCH 

4x elastomer spacers (th.3mm) 

8x mounting bolts (M6) 

23mm 