16
BR 500, BR 550, BR 600
:
Hold the rope rotor steady.
:
Pull out the rope with the starter
grip and straighten it out.
– Hold the starter grip firmly to keep
the rope tensioned.
452RA016
VA
– Let go of the rope rotor and
slowly release the starter grip so
that the rope winds itself onto the
rotor.
The starter grip must sit firmly in the
rope guide bushing without
drooping to one side. If this is not
the case, tension the spring by one
additional turn.
452RA160
VA
When the starter rope is fully
extended, it must still be possible to
rotate the rope rotor at least another
half turn before maximum spring
tension is reached. If this is not the
case, pull the rope out, hold the
rope rotor steady and take off one
turn of the rope.
Do not overtension the rewind
spring as this will cause it to break.
Install in the reverse sequence.
– Remove the starter cover with
rewind starter,
b
5.2
:
Take out the screws (arrows)
452RA024
VA
:
Lay the unit on its back.
452RA161
VA
5.9
Shroud