36
BR 500, BR 550, BR 600
– Remove the carburetor,
b
6.2.2
– Loosen the muffler mounting
screws,
b
7.6
:
Seal the impulse hose (1) with a
suitable plug.
2
1
452RA110
VA
:
Mount the test flange
1119 850 4201 (2) to the
manifold with suitable screws.
:
Slide the sealing plate
0000 855 8106 (1) between the
muffler and cylinder exhaust port.
– Tighten the muffler mounting
screws moderately.
452RA111
VA
1
The sealing plate must completely
fill the space between the screws.
– Set the piston to top dead center.
– Perform vacuum test,
b
7.8.2
– Perform pressure test,
b
7.8.3
Oil seals tend to fail when subjected
to a vacuum, i.e. the sealing lip lifts
away from the crankshaft during the
piston's induction stroke because
there is no internal counterpressure.
A test can be carried out with the
vacuum pump to detect this kind of
fault.
– Carry out the preparations,
b
7.8.1
:
Connect suction hose (1) of
vacuum pump 0000 850 3501 to
nipple (arrow) of the test flange.
452RA112
VA
1
:
Close the vent screw (1) on the
pump.
:
Operate the lever (2) until the
pressure gauge (3) indicates a
vacuum of 0.5 bar.
452RA113
VA
3
2
1
7.8.1
Preparations
7.8.2
Vacuum Test
RA_452_00_01_02.book Seite 36 Donnerstag, 16. Februar 2012 11:52 11