5.8.2
Solenoid Valve
Generator wire
Route the cable starting at the generator in the
direction of the solenoid valve (see
b
5.8.1).
.
Insert bushing (
1
)
.
Insert shrink tube as far as it will go (
A
)
.
Press in and/or insert wires (
2
) in the marked
locations (arrows)
.
Connect the generator plug (
3
) to the solenoid
valve
Short circuit wire
Route the short circuit wire starting at the air baffle
in the direction of the solenoid valve (see
b
5.8.3).
.
Insert bushing (
4
)
.
Press in and/or insert short circuit wire (
5
) in the
marked location (arrow)
.
Connect the plug (
6
) of the short circuit wire to
the solenoid valve
5.8.3
Air Baffle
Short circuit wire
.
Insert the blue shrink tube (
1
) into the air baffle
as far as it will go (
A
)
.
Press in and/or insert short circuit wire (
2
) in the
marked locations (arrows)
.
Slide the bushing (
3
) over the black shrink tube
A
3
370TI067 KN
4
1
2
5
6
A
370TI068 KN
1
2
3