70
MS 271 C, MS 291 C
10.
Control Levers
10.1
Master Control Lever
The positions of the Master Control
lever are described in the instruction
manual.
10.1.1 Removing and Installing
– Remove the air filter,
b
12.1
– Remove the choke rod,
b
10.3.3
– Set the switch lever (1) to "
0
".
:
Pry out the switch lever (1) at the
opening (arrow) and remove it,
lifting the contact spring (2)
slightly at the same time
– no more than 2 mm.
– Remove the short circuit wire (1)
from the switch lever,
b
7.7.2
:
Remove the switch lever (2),
check it and replace if necessary.
2710RA192 TG
1
2
5902RA584 TG
1
2
Installing
– Place the switch lever (2) in
position.
– Fit the short circuit wire (1) on the
switch lever,
b
7.7.2
:
When installing the switch lever,
lift the contact spring (1) a little
– no more than 2 mm.
:
Push the switch lever (1) onto the
filter base's pivot pin (2) until it
snaps into position.
5902RA584 TG
1
2
2710RA155 TG
1
2710RA193 TG
1
2
:
Check operation.
– Short circuit wire's ring terminal
must touch the contact
spring (arrow) in position "
0
".
– Reassemble all other parts in the
reverse sequence.
10.2
Throttle Trigger/Lockout
Lever
:
To remove the handle molding,
press the tabs (1) on the
underside apart and push them
through the rear handle.
5902RA264 TG
5902RA307 TG
1
1