SR 200
English
21
Metering Knob
N
Rotate the metering knob (1) for
infinitely variable discharge rate
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (2) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Discharge rate (l/min) with pressure
pump (special accessory)
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Checking Flow Rate
N
Place the unit on the ground.
N
Fill the container with water up to
10 liter mark.
Machines without pressure pump
N
Set the "standard" metering knob to
6.
N
Start the machine.
N
Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 110 and
150 seconds.
Machines with pressure pump (special
accessory)
N
Fit metering knob 2.0 in the nozzle.
N
Start the machine.
N
Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 100 and
130 seconds.
2
1
2431BA022 KN
081
1BA019 KN
Spray tube angle
Knob setting
- 30°
0°
+ 30°
1
0.24
0.17
0.11
2
0.82
0.66
0.46
3
1.42
1.13
0.84
4
2.2
1.66
1.1
5
2.69
2.13
1.46
6
2.91
2.25
1.52
Spray tube angle
Knob setting
- 30°
0°
+ 30°
0.5
0.05
0.04
0.03
0.65
0.08
0.07
0.05
0.8
0.12
0.09
0.08
Spray tube angle
Knob setting
- 30°
0°
+ 30°
1.0
0.64
1.6
1.7
2.0
2.59
Spray tube angle
Knob setting
- 30°
0°
+ 30°
0.5
0.15
0.65
0.2
0.8
0.37