SR 5600
English
17
Stop Cock
N
Stock cock (1) at right angle to
control handle = closed
N
Stock cock (1) parallel to control
handle = open
N
Adjust the discharge rate with the
metering knob – not the stop cock.
Metering Knob
N
The discharge rate can be infinitely
varied by turning the metering
knob (2) on the nozzle (3).
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (4) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Discharge rate (l/min) with pressure
pump (special accessory)
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Metering Unit
1
081
1BA013 KN
2
4
1
6
5
4
3
2
372BA005 KN
3
081
1BA019 KN
Spray tube angle
Knob setting
- 30°
0°
+ 30°
1
0,28
0,28
0,2
2
0,92
0,85
0,79
3
2,22
1,73
1,33
4
2,96
2,36
1,75
5
3,41
2,7
2,03
6
3,62
2,91
2,19
Spray tube angle
Knob setting
- 30°
0°
+ 30°
0,5
0,1
0,09
0,08
0,65
0,12
0,12
0,1
0,8
0,16
0,15
0,14
Spray tube angle
Knob setting
- 30°
0°
+ 30°
1,0
0,75
0,74
0,74
1,6
2,12
2,02
1,98
2,0
3,15
3,09
3,06
Spray tube angle
Knob setting
- 30°
0°
+ 30°
0,5
0,19
0,18
0,18
0,65
0,29
0,28
0,27
0,8
0,48
0,47
0,47