11.6.2 Checking the tank vent
Test preparations
– Open the filler cap and drain the
fuel tank in accordance with
regulations,
– Close the filler cap
– Remove the shroud,
– Remove the control unit,
– Remove the air filter,
:
Pull off the fuel suction hose (1)
at the connector (arrow)
:
Close the fuel suction hose (1)
with the plug (2) and push the
hose (3) of the pump (4)
0000 850 1300 onto the
support of the fuel intake
1307RA203 TG
1
1307RA204 TG
2
3
4
1
Testing with negative pressure
:
Slide ring (1) to the left and
connect the pump (2)
0000 850 1300 to the fuel tank
with negative pressure
Pressure is equalized via the tank
vent. A negative pressure must not
build up inside the tank.
– Clean the area around the tank
vent
– Replace tank vent if necessary,
– Continue with "Testing with
gauge pressure"
Testing with gauge pressure
The same preparatory steps are
required as for the testing with
negative pressure.
– Before testing with gauge
pressure – Complete testing
with negative pressure
1307RA205 TG
1
2
:
Slide ring (1) to the right and
connect the pump (2)
0000 850 1300 to the fuel tank
with overpressure
Actuate the pump until the pressure
gauge shows a pressure of 0.3 bar.
If this pressure remains constant for
at least 20 seconds, the tank vent
and tank are airtight. If the pressure
drops, replace the tank vent.
– After testing, slide the ring on the
pump to the left to vent the pump
and disconnect the hose from the
support of the connecting
element.
– Replace the fuel suction hose
between the injection pump and
connecting element,
– Fit air filter,
– Reassemble remaining parts in
reverse order