36
TS 500i
:
Fit the belt guard (1)
:
Insert and tighten the screw
(arrow)
:
Slide the starter (1) onto the
studs
:
Screw in the collar nuts (arrows)
– do not tighten
:
Turn the hexagon (1) on the
tensioner clockwise
370RA041 TG
1
370RA042 TG
1
370RA051 TG
1
– After roughly 1/8 of a turn, the
tensioner is caught by the force of
the spring. The hexagon is now
turned further by the spring
tension until the ribbed poly
V-belt is tensioned.
The hexagon must not be forced, as
the belt tension is obtained through
the spring tension.
– Screw all three collar nuts tight
– Insert the water hose in the
guides, starting from the solenoid
valve
4.6
Tensioner
– Remove the "cast arm with
guard",
:
Turn the hexagon (1) 1/2 turn
clockwise to relax the tensioner
:
Remove screws (2)
1307RA020 TG
2
1
2
:
Remove the complete
tensioner (1)
:
Remove the cover (1)
– Unhook the tensioner spring from
the clamping lever
– Examine the parts and replace
them if necessary
:
Hook the tensioner spring into the
hole (arrow) of the lever (1)
– Fit the cover
1307RA166 TG
1
370RA054 TG
1
370RA055 TG
1