Maintenance
5
Hydraulic systems
– Remove the hood of the technical compart-
ment.
To ensure correct operation of the truck
functions, the oil level must be between the
minimum mark (3) and maximum mark (2) on
the tank.
– Remove the plug (1). If necessary, top up
via the opening.
– Refit the plug (1) afterwards.
CAUTION
Risk of damage to hydraulic components
Only use hydraulic oil that complies with the manu-
facturer's specifications (see table of recommen-
ded lubricants).
– Refit the hood of the technical compart-
ment.
– Reconnect the battery connector.
– Return the truck to service.
Checking the controlled stabiliser
hydraulic system for leaks
– Switch off the truck and disconnect the
battery connector.
– Remove the hood of the technical compart-
ment.
– Inspect the stabiliser hydraulic system:
• Tank
• Rigid pipes
• Connections from the stabiliser directional
control valve block to the cylinders
– Check the tank for leaks.
– Tighten the swivel joints on the cylinders if
necessary.
– Check the cylinders for leaks.
– Check that the rigid pipes are attached
correctly and show no signs of friction wear.
– Refit the hood of the technical compart-
ment.
– Return the truck to service.
11638011651 EN - 09/2019
123
Summary of Contents for EXD-SF 20
Page 1: ...Original instructions Double pallet stacker EXD SF 20 0313 0346 11638011651 EN 09 2019 ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 19: ...2 Safety ...
Page 28: ...2 Safety Safety tests 18 11638011651 EN 09 2019 ...
Page 29: ...3 Overviews ...
Page 40: ...3 Overviews Markings 30 11638011651 EN 09 2019 ...
Page 41: ...4 Use ...
Page 113: ...5 Maintenance ...
Page 139: ...6 Technical specifications ...
Page 140: ...6 Technical specifications EXD SF 20 datasheet EXD SF 20 datasheet 130 11638011651 EN 09 2019 ...
Page 148: ......
Page 149: ......
Page 150: ...STILL GmbH 11638011651 EN 09 2019 ...