4
Use
Checks and actions prior to commissioning
Checking the emergency shutdown
To check the operation of the emergency off
switch, proceed as follows:
– Start up the truck.
– Drive the truck.
– Press the emergency off switch (1).
• The truck stops immediately
• The truck power supply is cut
• The electrical controls and motors are no
longer supplied with power
– Pull the emergency off switch (1).
The functions are available again.
NOTE
Ensure that the stabiliser wheels operate
correctly. This adjustment influences braking
effectiveness.
Checking the brake
NOTE
Perform this check on a flat surface.
– Drive the machine forward.
– Tilt the tiller in areas (1) and (2).
In these two areas, the machine is braked and
the drive unit is no longer powered.
Releasing the tiller in the drive area (3) sends
the tiller into area (1) and cuts traction.
38
11638011651 EN - 09/2019