Use
4
Handling the battery
Do not pull the emergency stop handle. This
operation cuts off the circuits and stops the
battery from charging.
– Connect the charger plug (1) to a mains
socket.
Phase
Green LED
Red LED
Mains socket
disconnected Off
Off
Charging
phases
Flashing
Off
Stopped-
/Equalisa-
tion/Mainte-
nance phase
Continuously
lit
Off
Charging
process too
long
Off
Continuously
lit
Charger
polarity
reversed
(+battery
and -battery
charger
cables
reversed, with
the battery
remaining
normally
connected
to the truck
assembly)
Continuously
lit
Continuously
lit
Battery
polarity
reversed
Off
Off
Selector
in neutral
position
Flashing
Flashing
CAUTION
Risk of damaging the battery
It is strictly prohibited to use an on-board charger
other than the one recommended.
11638011651 EN - 09/2019
89
Summary of Contents for EXD-SF 20
Page 1: ...Original instructions Double pallet stacker EXD SF 20 0313 0346 11638011651 EN 09 2019 ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 19: ...2 Safety ...
Page 28: ...2 Safety Safety tests 18 11638011651 EN 09 2019 ...
Page 29: ...3 Overviews ...
Page 40: ...3 Overviews Markings 30 11638011651 EN 09 2019 ...
Page 41: ...4 Use ...
Page 113: ...5 Maintenance ...
Page 139: ...6 Technical specifications ...
Page 140: ...6 Technical specifications EXD SF 20 datasheet EXD SF 20 datasheet 130 11638011651 EN 09 2019 ...
Page 148: ......
Page 149: ......
Page 150: ...STILL GmbH 11638011651 EN 09 2019 ...