Use
4
Operating the FleetManager™ option
FleetManager™ option: Colour code
for the LEDs
The LEDs can have different statuses and
different colours. Below is the list of the most
common messages and their meanings.
Malfunction
Cause
Solution
LED status
LED 1
LED 2
Signal transmitter
Reading device
variant: no
valid access
authorisation
Keypad variant:
no valid access
authorisation for
the PIN code
entered
Generate a
valid access
authorisation
using the interface
Lit continuously
Red colour
Off
A long acoustic
signal sounds
Keypad variant:
PIN code entered
incorrect or not
confirmed using
the Enter key
Re-enter the PIN
code
The operator
has been
granted access
authorisation.
But the period
of validity has
expired.
Use the interface
to enter a new
period of validity
Lit continuously
Red colour
Flashes once
Green colour
A long acoustic
signal sounds
The date of the
truck is incorrect
Update the date
of the truck
Flashes quickly
Yellow colour
Lit continuously
Green colour
Memory is 80%
full
Clear the memory
Flashes quickly
Red colour
Flashes quickly
Red colour
A long acoustic
signal sounds
upon activation
There are several
possible causes:
- Reading device
or keypad not
accessible
- GPRS module
not accessible
- Built-in
rechargeable
battery flat
- Memory full
Contact the
After-Sales
Service Centre
11638011651 EN - 09/2019
61
Summary of Contents for EXD-SF 20
Page 1: ...Original instructions Double pallet stacker EXD SF 20 0313 0346 11638011651 EN 09 2019 ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 19: ...2 Safety ...
Page 28: ...2 Safety Safety tests 18 11638011651 EN 09 2019 ...
Page 29: ...3 Overviews ...
Page 40: ...3 Overviews Markings 30 11638011651 EN 09 2019 ...
Page 41: ...4 Use ...
Page 113: ...5 Maintenance ...
Page 139: ...6 Technical specifications ...
Page 140: ...6 Technical specifications EXD SF 20 datasheet EXD SF 20 datasheet 130 11638011651 EN 09 2019 ...
Page 148: ......
Page 149: ......
Page 150: ...STILL GmbH 11638011651 EN 09 2019 ...