5
Maintenance
Maintenance every 1000 hours
Battery maintenance
The operations described below relate to
lead batteries with liquid electrolyte. For
batteries with gel electrolyte, which are said
to be "maintenance-free", please refer to the
manufacturer’s instructions.
WARNING
Risk of serious injury and/or serious damage to
equipment.
Avoid contact with the acid. Do not create a short-
circuit. Refer to the recommendations in the daily
checks section. The electrolyte contains sulphuric
acid, which is a hazardous product. Wear gloves
and goggles when working on the battery. In case
of contact with eyes or skin, rinse immediately with
clean water, then seek medical advice if necessary.
Charging the battery releases hydrogen, which can
create an explosive mixture. Do not create sparks,
do not smoke and keep naked flames away from
a battery which is being charged or has recently
been charged. To prevent the accumulation of
hydrogen, keep the battery cover open during
charging. Charge the battery in a well-ventilated
room. Do not place metal objects on the battery as
there is a risk of creating a short-circuit.
Electrical equipment, testing electrolyte
level and topping up with water
This check and any topping up required should
be carried out every week, after charging an
open lead battery only.
– Switch off the ignition, open the bonnet,
unplug the battery connector.
– Check the level, which should be up to the
base of the plug, slightly above the splash
guard.
– Add distilled water to top up cells with a low
water level.
– Then refit the plugs.
CAUTION
Deterioration or destruction of the equipment
Only top up with distilled water. Never top up before
charging (risk of overflow). Do not overfill the cells.
100
1170 801 15 09 [EN]
Summary of Contents for EXG-10
Page 2: ......
Page 7: ...1 Introduction ...
Page 20: ...1 Introduction Environmental considerations 14 1170 801 15 09 EN ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 39: ...4 Use ...
Page 82: ...4 Use Putting Out of Commission and Storage 76 1170 801 15 09 EN ...
Page 83: ...5 Maintenance ...
Page 123: ...6 Technical data ...
Page 135: ......
Page 136: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...
Page 138: ......
Page 139: ...7 Diagrams ...
Page 146: ...7 Diagrams Electrical installation 140 1170 801 15 09 EN ...
Page 148: ...7 Diagrams Electrical installation 142 1170 801 15 09 EN ...
Page 150: ...7 Diagrams Electrical installation 144 1170 801 15 09 EN ...
Page 151: ...Diagrams 7 Electrical installation Mast tilt option EXG10 EXG12 EXG16 1170 801 15 09 EN 145 ...
Page 152: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...