Overviews
3
Controls and display
DESIGNATION
EXPLANATION
COMMENTS / SCREEN
MESSAGES
5
Control button "2"
To display the previous
screen
Alternative function: setting
button
6
Control button "3"
Truck off button
With Digicode option only
7
Control button "4"
SET
To access control screens
8
Digicode keypad
To enter operator’s or
service engineer’s personal
ID code
Option preventing use by
unauthorised personnel.
Default user code: 1-2-3-4
(factory setting)
9
Active button indicator
10 Date display
See "Setting the date and
time"
11 Time display
See "Setting the date and
time"
12
"STOP INDICATOR LIGHT"
red indicator light
Various faults
1) Message: "Motor fault"
- Try to restart by resetting
ignition key
- Alarm still active: Call
service engineer
2) Message: "Brake worn "+
audible alarm
- Alarm still active: Call
service engineer
13
"BATTERY ALARM"
red indicator light
1) Flashing: charge < or =
10%
2) Lit: battery discharged
1)->Recharge recom-
mended
Message: "Low battery
charge level"
2)-> Lifting disabled
->Recharge essential
Message: "Battery level=0%
Lifting restricted"
14
Temperature alarm indicator
light (red)
Lit: control module
overheated
-> Truck is stopped
Message: "T° fault"
In general, wait for the truck
to cool down and then restart
it.
15
Operator presence indicator
(green)
Flashes for 5 seconds after
switching on Lights when the
operator is on the platform.
Self-test before truck is
started.
16
"Maintenance display"
red indicator light
1) Flashing: service
recommended in:...
2) Lit: service required
immediately
1) Message: "Next
inspection in X days or in
Y hours"
2) Message: "Service
inspection required today".
1170 801 15 09 [EN]
29
Summary of Contents for EXG-10
Page 2: ......
Page 7: ...1 Introduction ...
Page 20: ...1 Introduction Environmental considerations 14 1170 801 15 09 EN ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 39: ...4 Use ...
Page 82: ...4 Use Putting Out of Commission and Storage 76 1170 801 15 09 EN ...
Page 83: ...5 Maintenance ...
Page 123: ...6 Technical data ...
Page 135: ......
Page 136: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...
Page 138: ......
Page 139: ...7 Diagrams ...
Page 146: ...7 Diagrams Electrical installation 140 1170 801 15 09 EN ...
Page 148: ...7 Diagrams Electrical installation 142 1170 801 15 09 EN ...
Page 150: ...7 Diagrams Electrical installation 144 1170 801 15 09 EN ...
Page 151: ...Diagrams 7 Electrical installation Mast tilt option EXG10 EXG12 EXG16 1170 801 15 09 EN 145 ...
Page 152: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...