Handling the battery
Handling the battery
Battery charging with an external
charger
– After use, move the truck to the charging
station.
– Stop the truck, lower the forks and switch off
the ignition.
– Press the emergency stop switch (1).
– Open the cover on the battery compart-
ment.
– Disconnect the battery connector (refer to
chapter 5 on disconnecting and connecting
the battery connector).
– Plug the battery connector into the socket
on the charging station.
– Now switch the charger on as directed in its
specific instructions.
– When charging is complete and the charger
has stopped, unplug the charger and
reconnect the battery connector to the truck.
– Close the cover on the battery compart-
ment.
– Check the charge status on the truck’s
multifunction indicator (2) after pulling out
the emergency stop switch and switching
on. The truck is now ready for use.
WARNING
Risk of serious injury and/or serious damage to
equipment.
To avoid any sparks, connect the battery connector
before switching the battery charger on and discon-
nect it after switching the charger off.
– Make sure that the charger is compatible
with the truck’s battery in terms of voltage
and charging current (refer to the instruc-
tions for the charger).
– Gel electrolyte batteries require a specific
setting for the discharge indicator and the
charger.
68
1170 801 15 09 [EN]
Summary of Contents for EXG-10
Page 2: ......
Page 7: ...1 Introduction ...
Page 20: ...1 Introduction Environmental considerations 14 1170 801 15 09 EN ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 39: ...4 Use ...
Page 82: ...4 Use Putting Out of Commission and Storage 76 1170 801 15 09 EN ...
Page 83: ...5 Maintenance ...
Page 123: ...6 Technical data ...
Page 135: ......
Page 136: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...
Page 138: ......
Page 139: ...7 Diagrams ...
Page 146: ...7 Diagrams Electrical installation 140 1170 801 15 09 EN ...
Page 148: ...7 Diagrams Electrical installation 142 1170 801 15 09 EN ...
Page 150: ...7 Diagrams Electrical installation 144 1170 801 15 09 EN ...
Page 151: ...Diagrams 7 Electrical installation Mast tilt option EXG10 EXG12 EXG16 1170 801 15 09 EN 145 ...
Page 152: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...