PROGRAMMING MODE — to be carried out with the truck switched off (2)
Restoring
the initial
administrator
code
To reactivate the default
administrator code
(00000000), please
contact your agent or
nearest dealer.
Activating the
automatic
switch-off
* * 2 * 1 #
red flashing green
flashing (5) (5 s before
switch-off)
The power supply
switches off
automatically after
10 min. (600 s by
default) if the truck is
not being used.
Setting the delay
of the automatic
switch-off
* * 3 * 6 0 #
red off green flashing
(2)(value accepted)
Example: automatically
switches off after 1 min.
(60 s) if not used.
Minimum setting = 10 s
/ maximum = 3000 s
Deactivating
the automatic
switch-off
* * 2 * 0 #
red off green flashing
(2)(command accepted)
Stand-by
NOTE
The stand-by function is only available with
the Digicode option.
To prolong battery life, the truck can be put
into energy-saving mode when it is not in use.
After a certain period of downtime, the truck
switches off.
This time period can be configured between 0
and 10 minutes. This function is disabled by
default.
Timeout can be adjusted. Contact the Tech-
nical Service Department authorised by the
manufacturer.
45758043402 [EN]
59
Summary of Contents for EXP 14
Page 2: ......
Page 7: ...1 Introduction ...
Page 16: ...1 Introduction Environmental considerations 10 45758043402 EN ...
Page 17: ...2 Safety ...
Page 29: ...3 Overview ...
Page 67: ...4 Use ...
Page 103: ...5 Maintenance ...
Page 116: ...5 Maintenance Putting out of commission 110 45758043402 EN ...
Page 117: ...6 Technical data ...
Page 133: ...Technical data 6 EXP overall dimensions EXP overall dimensions 45758043402 EN 127 ...
Page 140: ...6 Technical data Supply table 134 45758043402 EN ...
Page 142: ...Index g Types of lifting masts 43 Triplex 44 U Update of this manual 4 136 45758043402 EN ...
Page 143: ......
Page 144: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 45758043402 EN ...