4
Operation
Replacing and transporting the battery
The deep discharge progresses in three
phases:
1
At the start of the deep discharge, the
customer can still charge the battery
himself for a limited period
2
If the deep discharge continues, only the
authorised service centre can put the
battery back into service
3
If the deep discharge continues beyond
the first two phases, the battery is
irreparably damaged
Time periods for putting back into service (guide values)
Battery 4.1 (9.8 kWh)
Battery 4.2, 4.3 (39.2 kWh)
Recommissioning
Phase 1: Approx. 8 days
Phase 1: Approx. 32 days
Customer (charging the
battery)
Phase 2: Approx. 97 days more Phase 2: Approx. 97 days more
Authorised service centre
Phase 3: The battery is irreparably damaged.
No longer possible
Display on the battery indicator during deep discharge
Phase of the deep discharge
Display on the battery indicator
Phase 1:
Start of the deep discharge. It is no longer possible
to drive the truck. In this phase, the customer can still
charge the battery himself using the battery charger.
Initially:
The last charge state LED flashes red.
Later:
The battery display is OFF.
The service LED lights up red.
Phase 2:
In this phase, the authorised service centre can put
the battery back into service. If the battery is not
put back into service during this period, it will be
irreparably damaged.
Phase 3:
The battery is irreparably damaged.
The battery display is OFF.
The service LED is OFF.
.
Replacing and transporting the battery
Commissioning batteries that are
delivered separately
Proper commissioning must be performed if
the truck was ordered without a battery or if it
242
50988078001 EN - 10/2018
Summary of Contents for FM-X EW Series
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 32: ...1 Foreword Environmental considerations 20 50988078001 EN 10 2018 ...
Page 33: ...2 Safety ...
Page 66: ...2 Safety Emissions 54 50988078001 EN 10 2018 ...
Page 67: ...3 Overviews ...
Page 85: ...4 Operation ...
Page 297: ...5 Maintenance ...
Page 304: ...5 Maintenance General maintenance information 292 50988078001 EN 10 2018 ...
Page 318: ...5 Maintenance Maintaining operational readiness 306 50988078001 EN 10 2018 ...
Page 319: ...6 Technical data ...
Page 350: ...6 Technical data Battery specifications for lithium ion batteries 338 50988078001 EN 10 2018 ...
Page 358: ......
Page 359: ......
Page 360: ...STILL GmbH 50988078001 EN 10 2018 ...