Operation
5
Driving
NOTE
The drive direction can also be changed during
travel. Your foot can remain on the accelerator
pedal while doing so. The truck decelerates
and is then accelerated again in the opposite
direction (reversing).
NOTE
In the event of an electrical fault with the
accelerator the drive unit is shut down. The
electrical brake (service brake) causes the
truck to decelerate. The truck cannot be driven
again until the accelerator pedal has been
released and then actuated again, provided
the electrical fault has been corrected. If the
truck still cannot be operated, park it securely
and contact your authorised service centre.
Starting drive mode, dual-pedal
version (variant)
DANGER
Being trapped under a rolling or tipping truck could
cause fatal injuries.
– Sit down on the driver’s seat.
– Fasten the seat belt.
– Activate the available restraint systems.
Observe the information in the chapter entitled
Safety regulations when driving.
The driver’s seat is equipped with a seat
switch. This checks whether the driver’s
seat is occupied. If it is not occupied or in
the case of malfunction of the seat switch, the
truck cannot be moved and all lifting functions
are locked. In this situation, the message
SEAT SWITCH
appears on the operating unit
display.
– Lift the fork carriage until the necessary
ground clearance is achieved.
– Tilt the lift mast backwards.
– Release the parking brake.
170525 EN - 10/2016
115
Summary of Contents for RX60-16
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 170525 EN 10 2016 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 58: ...3 Safety Emissions 46 170525 EN 10 2016 ...
Page 59: ...4 Overviews ...
Page 61: ...Overviews 4 General view of truck 170525 EN 10 2016 49 ...
Page 81: ...5 Operation ...
Page 344: ...5 Operation Cleaning 332 170525 EN 10 2016 ...
Page 345: ...6 Maintenance ...
Page 348: ...6 Maintenance General maintenance information 336 170525 EN 10 2016 ...
Page 352: ...6 Maintenance General maintenance information 340 170525 EN 10 2016 ...
Page 389: ...7 Technical data ...
Page 410: ......
Page 411: ......
Page 412: ...STILL GmbH 170525 EN 10 2016 ...