5
Operation
Working with loads
NOTE
The method of operating the lifting system
depends on the operating devices included in
the truck’s equipment.
– Ensure that the truck has been in operation
for a period of time before carrying out the
load measurement.
– Set lift mast to vertical.
– Raise the fork to a height of 300–800 mm.
– Ensure that the load is at rest.
6210_003-072_V2
2
1
– Press button (1) for "load measurement";
the "load measurement" symbol (2) ap-
pears on the display highlighted in black.
NOTE
If the truck is equipped with mini-levers or
fingertip operation, the "F1" button can also be
pressed as an alternative.
NOTE
During the following process, the fork carriage
must be lowered slightly and then stopped
abruptly. While doing so, the fork must
not touch the ground, otherwise the load
measurement will not be accurate. To stop
the lowering procedure quickly, release the
operating device for lowering so that it jumps
into the zero position.
– Lower the fork carriage slightly and release
the operating device.
NOTE
When stopping the lowering process the
load must be cushioned in order to create a
measurable impulse.
158
170525 EN - 10/2016
Summary of Contents for RX60-16
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 170525 EN 10 2016 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 58: ...3 Safety Emissions 46 170525 EN 10 2016 ...
Page 59: ...4 Overviews ...
Page 61: ...Overviews 4 General view of truck 170525 EN 10 2016 49 ...
Page 81: ...5 Operation ...
Page 344: ...5 Operation Cleaning 332 170525 EN 10 2016 ...
Page 345: ...6 Maintenance ...
Page 348: ...6 Maintenance General maintenance information 336 170525 EN 10 2016 ...
Page 352: ...6 Maintenance General maintenance information 340 170525 EN 10 2016 ...
Page 389: ...7 Technical data ...
Page 410: ......
Page 411: ......
Page 412: ...STILL GmbH 170525 EN 10 2016 ...