3
Safety
Safety inspections
– For insulation testing, contact the autho-
rised service centre.
The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck’s electrical system and drive batte-
ries must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal
voltage U
Batt
Test values
50 VDC
24 V
> 1200
100 VDC
48 V
> 2400
Battery
100 VDC
Batt+
Batt-
Battery tray
80 V
> 4000
.
Test values for the entire truck
Nominal
voltage
Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 V
50 VDC
Min. 50 k
> 24 k
48 V
100 VDC
Min. 100 k
> 48 k
80 V
100 VDC
Min. 200 k
> 80 k
.
38
170525 EN - 10/2016
Summary of Contents for RX60-16
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 170525 EN 10 2016 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 58: ...3 Safety Emissions 46 170525 EN 10 2016 ...
Page 59: ...4 Overviews ...
Page 61: ...Overviews 4 General view of truck 170525 EN 10 2016 49 ...
Page 81: ...5 Operation ...
Page 344: ...5 Operation Cleaning 332 170525 EN 10 2016 ...
Page 345: ...6 Maintenance ...
Page 348: ...6 Maintenance General maintenance information 336 170525 EN 10 2016 ...
Page 352: ...6 Maintenance General maintenance information 340 170525 EN 10 2016 ...
Page 389: ...7 Technical data ...
Page 410: ......
Page 411: ......
Page 412: ...STILL GmbH 170525 EN 10 2016 ...