Safety
2
Safety tests
The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck's electrical system and drive batte-
ries must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal voltage
U
Batt
Test values
50 VDC
24 volts
> 1200 Ω
100 VDC
48 volts
> 2400 Ω
Battery
100 VDC
Batt+
Batt-
Battery tray
80 volts
> 4000 Ω
.
Test values for the entire truck
Nominal voltage Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 volts
50 VDC
Min. 50 kΩ
> 24 kΩ
48 volts
100 VDC
Min. 100 kΩ
> 48 kΩ
80 volts
100 VDC
Min. 200 kΩ
> 80 kΩ
.
56338011803 EN - 02/2019 - 09
49
www.
duma
-rent.com
Summary of Contents for RX60-25
Page 2: ...www duma rent com ...
Page 4: ...www duma rent com ...
Page 14: ...www duma rent com ...
Page 15: ...1 Foreword www duma rent com ...
Page 38: ...1 Foreword Environmental considerations 24 56338011803 EN 02 2019 09 www duma rent com ...
Page 39: ...2 Safety www duma rent com ...
Page 71: ...3 Overviews www duma rent com ...
Page 73: ...Overviews 3 General view 56338011803 EN 02 2019 09 59 www duma rent com ...
Page 87: ...4 Operation www duma rent com ...
Page 384: ...4 Operation Decommissioning 370 56338011803 EN 02 2019 09 www duma rent com ...
Page 385: ...5 Maintenance www duma rent com ...
Page 392: ...5 Maintenance General maintenance information 378 56338011803 EN 02 2019 09 www duma rent com ...
Page 396: ...5 Maintenance General maintenance information 382 56338011803 EN 02 2019 09 www duma rent com ...
Page 433: ...6 Technical data www duma rent com ...
Page 458: ...6 Technical data Fuse assignment 444 56338011803 EN 02 2019 09 www duma rent com ...
Page 469: ...www duma rent com ...
Page 470: ...STILL GmbH 56338011803 EN 02 2019 09 www duma rent com ...