PowerPlusLife
®
error messages
One of the three LEDs is always lit up to indi-
cate the cooling status of the PowerPlusLife
®
battery. If an LED changes from being perma-
nently illuminated to flashing, it indicates that
an error message has been generated. The
error message is independent of the colour of
the LED. In the event of a fault, it is always the
LED that is currently illuminated that flashes.
The following error messages are indicated by
a flashing LED:
Fluid level
The fluid level in the PowerPlusLife
®
battery is
checked by a sensor.
If an LED slowly flashes alternately, it indi-
cates that the fluid level is too low.
–
Top up the fluid; see the chapter entitled
"Servicing the battery".
Internal error
If an LED flashes at frequent intervals, it indi-
cates the presence of an internal fault.
The error can be read using the diagnostics
function. The diagnostic connector (1) is loca-
ted on the battery management device, on the
right alongside the LEDs.
–
Contact your authorised service centre.
Red LED
Yellow LED
Green LED
1
2
3
1
6341_003-046
Diagnostic connector
1
Operating
4
PowerPlusLife battery
297
56358042501 EN - - 11
Summary of Contents for RX60-60
Page 2: ......
Page 13: ...1 Foreword ...
Page 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Page 41: ...2 Safety ...
Page 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operating ...
Page 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Page 337: ...5 Maintenance ...
Page 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Page 381: ...6 1000 hour maintenance annual mainte nance ...
Page 385: ...7 Technical data ...
Page 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Page 407: ......
Page 408: ...STILL GmbH 56358042501 EN 11 ...