Decommissioning
Shutting down and storing the
truck
CAUTION
Component damage due to incorrect storage!
Storing the truck improperly or decommissioning the
truck for more than two months will result in corro-
sion on the truck. If the truck is parked in an area
with an ambient temperature of below -10°C for an
extended period, the batteries will cool down. The
electrolyte may freeze and damage the batteries.
–
Implement the following measures before shutting
down.
CAUTION
Risk of damage to the battery male connector when
disconnecting!
If the battery male connector is disconnected while
the key switch is switched on under load, an arc will
be produced. The arc can damage the contacts and
considerably shorten the service life of the contacts.
–
Switch off the key switch.
–
Only disconnect the battery male connector while
the key switch is switched off.
CAUTION
Tyre deformation as a result of continuous loading on
one side!
Keeping all wheels clear of the ground prevents per-
manent deformation of the tyres.
–
Have the truck raised and jacked up by the au-
thorised service centre.
CAUTION
Danger of damage from corrosion due to condensa-
tion on the truck!
Many plastic films and synthetic materials are water-
tight. Condensation water on the truck cannot es-
cape through these covers.
–
Do not use plastic film as this facilitates the forma-
tion of condensation water.
NOTE
Only store batteries that are fully charged.
Operating
4
Decommissioning
321
56358042501 EN - - 11
Summary of Contents for RX60-60
Page 2: ......
Page 13: ...1 Foreword ...
Page 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Page 41: ...2 Safety ...
Page 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operating ...
Page 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Page 337: ...5 Maintenance ...
Page 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Page 381: ...6 1000 hour maintenance annual mainte nance ...
Page 385: ...7 Technical data ...
Page 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Page 407: ......
Page 408: ...STILL GmbH 56358042501 EN 11 ...