The insulation testing results must be at least
the test values given in the following two
tables.
–
For insulation testing, contact the author-
ised service centre.
The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck's electrical system and drive batter-
ies must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal volt-
age U
Batt
Test values
Battery
50 VDC
Batt+
Batt-
Battery tray
24 volts
> 1200 Ω
100 VDC
48 volts
> 2400 Ω
100 VDC
80 volts
> 4000 Ω
Test values for the entire truck
Nominal volt-
age
Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 volts
50 VDC
Min. 50 kΩ
> 24 kΩ
48 volts
100 VDC
Min. 100 kΩ
> 48 kΩ
80 volts
100 VDC
Min. 200 kΩ
> 80 kΩ
Safety
2
Safety tests
49
56358042501 EN - - 11
Summary of Contents for RX60-60
Page 2: ......
Page 13: ...1 Foreword ...
Page 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Page 41: ...2 Safety ...
Page 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operating ...
Page 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Page 337: ...5 Maintenance ...
Page 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Page 381: ...6 1000 hour maintenance annual mainte nance ...
Page 385: ...7 Technical data ...
Page 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Page 407: ......
Page 408: ...STILL GmbH 56358042501 EN 11 ...