Disconnecting the battery male
connector
CAUTION
Risk of damage to the battery male connector when
disconnecting!
If the battery male connector is disconnected while
the key switch is switched on under load, an arc will
be produced. The arc can damage the contacts and
considerably shorten the service life of the contacts.
–
Switch off the key switch.
–
Only disconnect the battery male connector while
the key switch is switched off.
–
Do not disconnect the battery male connector
while under load, except in an emergency.
CAUTION
There is a risk of short circuit if the ca-
bles are damaged!
–
Do not crush the battery cable when
closing the battery cover.
–
Switch off the key switch.
–
Open the battery cover.
–
Pull the fastener (4) to the left and open the
fastener.
–
Disconnect the battery male connector (3)
from the plug connection by pulling the han-
dle (2) in the direction of the arrow.
–
Check the battery cable for damage.
6341_003-013_V2
2
4
3
Operating
4
Connecting and disconnecting the battery male connector
274
56358042501 EN - - 11
Summary of Contents for RX60-60
Page 2: ......
Page 13: ...1 Foreword ...
Page 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Page 41: ...2 Safety ...
Page 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operating ...
Page 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Page 337: ...5 Maintenance ...
Page 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Page 381: ...6 1000 hour maintenance annual mainte nance ...
Page 385: ...7 Technical data ...
Page 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Page 407: ......
Page 408: ...STILL GmbH 56358042501 EN 11 ...