Procedure in emergencies
Emergency shutdown
WARNING
Electrical and hydraulic functions will no longer be
available following an emergency shutdown!
The emergency shutdown procedure disables the hy-
draulic functions. The entire electrical system is de-
energised.
–
Only use this safety system in the event of an
emergency.
In drive mode, the emergency shutdown has
the following effect:
●
Regenerative braking is not available.
●
The regenerative brake will not hold the
truck on ascending or descending gradi-
ents. Actuate the service brake, otherwise
the truck will roll down gradients.
●
No speed reduction when you release the
accelerator pedal. The truck will coast.
●
Power steering is not available. Steering
forces are increased by the remaining
emergency steering function.
●
The "Curve Speed Control" system (auto-
matic reduction of speed when cornering) is
not available.
●
Hydraulic functions are not available.
In the event of an emergency, all electrical
and hydraulic functions can be switched off via
the emergency off switch or via the battery
male connector using the following proce-
dures:
Operating
4
Procedure in emergencies
303
56358042501 EN - - 11
Summary of Contents for RX60-60
Page 2: ......
Page 13: ...1 Foreword ...
Page 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Page 41: ...2 Safety ...
Page 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operating ...
Page 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Page 337: ...5 Maintenance ...
Page 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Page 381: ...6 1000 hour maintenance annual mainte nance ...
Page 385: ...7 Technical data ...
Page 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Page 407: ......
Page 408: ...STILL GmbH 56358042501 EN 11 ...