Maintenance
5
Providing access to maintenance points
7300_003-008
2
1
– If the gas spring is equipped with a position
lock (variant), open the bonnet until the
latch (1) of the gas spring (2) snaps into
place.
WARNING
Risk of injury from the bonnet lowering!
The bonnet is fitted with a gas spring that holds the
bonnet in the open position. When additional load is
present, for example heavy objects, strong wind or
other persons, the bonnet can lower suddenly.
Cold weather and ageing can also reduce the
performance of the gas spring and cause the
bonnet to lower.
– If the force of the gas spring is deteriorating,
replace the gas spring.
– If the gas spring has a position lock (variant),
make sure that the latch is engaged.
– To replace the gas spring, contact the authorised
service centre.
7300_003-008
2
1
Closing the bonnet
WARNING
When closing the bonnet, there is a risk of crushing!
When closing the bonnet, nothing must come
between the bonnet and the edge of the chassis.
– Do not grasp any edges. Always close the
bonnet by placing both hands on the handles.
CAUTION
Risk of damage!
The bonnet can be equipped with a gas spring (2)
with a position lock (variant). This prevents the
gas spring from being compressed. Exerting force
when closing the bonnet will damage the gas spring
or bonnet suspension.
– Before closing the bonnet, check whether the
gas spring is equipped with a position lock
(variant).
– If the gas spring is equipped with a position lock
(variant), release the latch (1) before closing the
bonnet.
57348011850 EN - 02/2019 - 11
331
Summary of Contents for RX70-40
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 33: ...2 Safety ...
Page 66: ...2 Safety Emissions 54 57348011850 EN 02 2019 11 ...
Page 67: ...3 Overviews ...
Page 78: ...3 Overviews Operating devices and display elements 66 57348011850 EN 02 2019 11 ...
Page 79: ...4 Operation ...
Page 320: ...4 Operation Decommissioning 308 57348011850 EN 02 2019 11 ...
Page 321: ...5 Maintenance ...
Page 328: ...5 Maintenance General maintenance information 316 57348011850 EN 02 2019 11 ...
Page 332: ...5 Maintenance General maintenance information 320 57348011850 EN 02 2019 11 ...
Page 334: ...5 Maintenance General maintenance information 322 57348011850 EN 02 2019 11 ...
Page 364: ...5 Maintenance Preserving operational readiness 352 57348011850 EN 02 2019 11 ...
Page 371: ...6 Technical data ...
Page 382: ...6 Technical data Fuse assignment 370 57348011850 EN 02 2019 11 ...
Page 391: ......