Operation
4
Switching on and starting
CAUTION
Lack of fuel can cause malfunctions!
If the fuel tank has been run empty, the fuel injection
system can draw in air bubbles. This can lead to
malfunctions in the fuel injection system.
When the fuel tank is replaced during repair work
or because it has been run empty, diesel fuel must
be pre-pumped with the fuel hand pump after filling,
see the "Using the fuel hand pump" chapter.
– Never run the fuel tank empty.
– If necessary, refuel the truck and pre-pump
diesel fuel.
NOTE
Additional information may appear on the
display.
– Refer to the information in the chapter
entitled "Display messages".
Access authorisation with PIN code
(variant)
Description
Trucks equipped with the "Access authori-
sation with PIN code" variant are protected
against unauthorised use by a five-digit driver
PIN. Up to fifty different driver PINs can be
defined so that the same truck can be used
by different drivers, each with their own driver
PIN.
NOTE
The driver PINs are defined in a truck control
unit menu that can only be accessed by
persons with the corresponding access
authorisation, e.g. fleet managers.
Once the key switch has been switched on,
the input menu for the driver PIN appears
on the display and operating unit screen. All
of the truck's functions (driving, hydraulics,
additional electrical installations and the
display and operating unit displays) are
blocked. The function of the hazard warning
system (variant) is guaranteed. Enter the five-
digit driver PIN (possible entries from 00000 to
99999) to enable the blocked functions. Once
57348011800 EN - 11/2018
97
Summary of Contents for RX70 Series
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 21: ...Foreword 1 Your truck 57348011800 EN 11 2018 9 ...
Page 38: ...1 Foreword Environmental considerations 26 57348011800 EN 11 2018 ...
Page 39: ...2 Safety ...
Page 53: ...Safety 2 Residual risk 57348011800 EN 11 2018 41 ...
Page 71: ...3 Overviews ...
Page 83: ...4 Operation ...
Page 321: ...5 Maintenance ...
Page 328: ...5 Maintenance General maintenance information 316 57348011800 EN 11 2018 ...
Page 330: ...5 Maintenance General maintenance information 318 57348011800 EN 11 2018 ...
Page 334: ...5 Maintenance General maintenance information 322 57348011800 EN 11 2018 ...
Page 378: ...5 Maintenance Remaining ready for operation 366 57348011800 EN 11 2018 ...
Page 379: ...6 1000 hour maintenance annual mainte nance ...
Page 383: ...7 Technical data ...
Page 391: ...Technical data 7 Ergonomic dimensions 57348011800 EN 11 2018 379 ...
Page 394: ...7 Technical data Fuse assignment 382 57348011800 EN 11 2018 ...
Page 404: ......
Page 405: ......
Page 406: ...STILL GmbH 57348011800 EN 11 2018 ...