background image

19 | 

P a g e

 

 

STEP 5.0

 

CORNER POST ASSEMBLY 

5.0 - ASSEMBLY PARTS 

 CORNER POST ASSEMBLY 

PART CODE  QTY 

DESCRIPTION 

CP 

1890mm Corner Post 

CP 

1805mm Corner Post 

40N 

24 

40mm Nail 

5.0 - ASSEMBLY 

 CORNER POST ASSEMBLY 

Hold corner post (CP) in position, nail through CP into wall stud using 6x 40N evenly 
spaced along CP. 2x 1805 CP at the front and 2x 1890 CP at the back.   

Note: Before nailing CPs, we recommend running a bead of silicone down the lines seen 
below.  

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Recommended: Run a bead of 

silicone down these two lines 

before nailing CPs 

Nail 6x 40N evenly 

spaced along CP 

Summary of Contents for S3105

Page 1: ...construct your shed is included inside the pack cedar panels doors windows hardware kits roof sheeting Please ensure you fully unpack all the parts check against the parts checklist before contacting customer service about anything you believe may be missing Thank you ...

Page 2: ...sembly area Review all instructions continue to refer to instructions throughout assembly step by step Preparing your site If you are installing your shed on the Stilla rebated floor we recommend finding a place in your yard that is very close to level Pavers or a solid material that will not be affected by weather can be used to perfectly level the shed by placing under the floor frame where requ...

Page 3: ... Step 1410x42x19mm 1 RS 1040mm Roof Sheeting 4 DH 6x3 Door Head 1800mm 1 DH 8x3 Door Head 300mm pcs 2 RS 1040mm Roof Sheeting 4 L 1040mm L Flashing ZINC 2 C 1283mm Channel ZINC 2 L 1300mm L Flashing ZINC 2 HK 8x3 Hardware Kit 1 IM 8x3 Instruction Manual 1 Floor Kit Option Floor Frame 140x38mm Part Code Checked Part Description Qty EP End Plate 1242x140x38mm 4 DJ Double Joist 824mm 2 SJ Single Jois...

Page 4: ...100BS 18 100mm Batten Screw 1 0 FLOOR FRAME 1 of 2 floor frames Fasten floor frame together as indicated in diagram below using lines and predrilled holes Screw through EP into DJ using 3x 100BS Screw through EP into SJ using 2 x 100BS per join Ensure frame is square by measuring from corner to corner diagonally frame will be square when both diagonal measurements equal the same REPEAT THIS PROCES...

Page 5: ...e joining the floor frames together as you go in order displayed in diagram below 1 Lay out frame in desired position and mark holes to dig as indicated on diagram below use shovel or marking paint 2 Dig and place logs in holes using concrete if you wish 3 Fasten floor frame to logs at desired height using 4x 100BS per log ensuring frame is level 4 Butt next floor frame into last installed frame a...

Page 6: ...NOG INSTALLATION PART CODE QTY DESCRIPTION FN 3 Floor Nog 376x42x35mm 65HHS 6 65mm Hex Head Screws 1 2 FLOOR NOG INSTALLATION Mark out measurements shown below centre of nog Fasten Floor Nogs FN in positions shown in diagram below using 1x 65HHS per join ...

Page 7: ...598x485mm FB 1 Floor Board 1798x326mm FB 1 Floor Board 598x326mm 50PS 34 50mm Philips Screw 1 3 FLOORING INSTALLATION Fasten floor sheets to floor frame as shown in diagram below using 50PS Bring Floor sheets in 43mm on all 4 sides from the outside of the floor frame Note The x marked on the floor sheets do not line up with out joists ...

Page 8: ...screw 1 0 ASSEMBLY WALL ASSEMBLY Screw through FP into LP top centre bottom using 3 x 65HHS Holding studs flush on the outside Note ensure tongue of cedar cladding is at the top on all panels LP Screw 3 x 65HHS Top centre bottom FP When screwing the four corners together please make sure the studs are flush on the outside not the inside as per image below ...

Page 9: ...ARTS WALL ASSEMBLY PART CODE QTY DESCRIPTION P 1 1200mm panel 65HHS 3 65mm hex head screw 2 1 ASSEMBLY WALL ASSEMBLY Screw through P into LP Top centre bottom using 3 x 65HHS holding studs flush on the outside P LP Screw 3 x 65HHS Top centre bottom ...

Page 10: ... PARTS WALL ASSEMBLY PART CODE QTY DESCRIPTION P 1 1200mm panel 65HHS 3 65mm hex head screw 2 2 ASSEMBLY WALL ASSEMBLY Screw through P into P Top centre bottom using 3 x 65HHS holding studs flush on the inside P Screw 3 x 65HHS Top centre bottom P ...

Page 11: ...op centre bottom using 3 x 65HHS holding studs flush on the outside STEP 2 4 WALL ASSEMBLY 2 4 ASSEMBLY PARTS WALL ASSEMBLY PART CODE QTY DESCRIPTION FP 1 Front panel 65HHS 3 65mm hex head screw 2 4 ASSEMBLY WALL ASSEMBLY Screw through FP into RP top centre bottom using 3 x 65HHS holding studs flush on the outside P Screw 3 x 65HHS Top centre bottom P RP P Screw 3 x 65HHS Top centre bottom P FP RP...

Page 12: ...PART CODE QTY DESCRIPTION DH 1 6x3 Door Head 1800mm DH 2 8x3 Door Head 300 pieces 40N 8 40mm Nail 2 5 ASSEMBLY DOOR HEAD INSTALLATION Place DH in position and fasten through DH into FP using 2 x 40N at each end Position 300 pieces at ends of DH and fasten into FP using 2x 40N per piece ...

Page 13: ...INSTALLATION 2 6 ASSEMBLY PARTS DOOR INSTALLATION PART CODE QTY DESCRIPTION DS 1 Door Step 40N 3 40mm Nail 2 6 ASSEMBLY DOOR INSTALLATION Nail through DS into floor frame if floor option was not chosen fasteners are not supplied DS ...

Page 14: ... 3 0 ASSEMBLY PARTS ROOF ASSEMBLY PART CODE QTY DESCRIPTION RS 4 1040mm roof sheet 3 0 ASSEMBLY ROOF ASSEMBLY Lay RS x 3 down on a flat hard surface and overlap until full measurement is 2565mm Bent up edge goes at the back of the shed ...

Page 15: ... L flashing C 2 1283mm C channel ST 12 Self tapping screw 3 1 ASSEMBLY ROOF ASSEMBLY Place L on RS Roof Sheets as shown in picture Screw through top 1 Rib in from each end and into each join of sheet 6 times all up using ST x 4 Slide C into place and repeat process Screw Screw Back Front Bent up edge L C ...

Page 16: ...m L flashing ST 6 Self tapping screw 3 2 ASSEMBLY ROOF ASSEMBLY Place L into position as shown in picture Screw through L into L at back and C at front Screw threw 1040L into roof sheet RS in centre repeat at both ends of the roof Screw Screw Note This drawing does not show the right number of ribs L L ...

Page 17: ...RS 36 40mm Roof screw 3 4 ASSEMBLY ROOF INSTALLATION Slide roof into position with L at back Roof must hang over back walls by 20mm and even hangover on side walls Screw through roofing rib into top plate of front and back wall panels starting in four corners on 2nd rib in Note Use a straight edge to keep screws in line ...

Page 18: ...HS per hinge Position Hinges are to be placed at top and bottom of door They are to be centralised over bracing on back of door as per second and third image below STEP 4 1 DOOR INSTALLATION 4 1 ASSEMBLY PARTS DOOR INSTALLATION PART CODE QTY DESCRIPTION D 2 Door HS 12 Hinge screw 4 1 ASSEMBLY DOOR INSTALLATION Hold door in position 3mm down from top Front of the door when closed will be flush with...

Page 19: ...l 12mm hole in marked position Repeat for bottom pad bolt Fasten Padbolts to door STEP 4 3 PAD BOLT INSALLATION 4 3 ASSEMBLY PARTS PAD BOLT INSTALLATION PART CODE QTY DESCRIPTION PB 1 Pad bolt fasten to door that is not pad bolted inside HS 6 Hinge Screw 4 3 ASSEMBLY PAD BOLT INSTALLATION Holding doors in closed position Hold PB centre of the door as shown in picture Screw through PB into door Hol...

Page 20: ...SSEMBLY CORNER POST ASSEMBLY Hold corner post CP in position nail through CP into wall stud using 6x 40N evenly spaced along CP 2x 1805 CP at the front and 2x 1890 CP at the back Note Before nailing CPs we recommend running a bead of silicone down the lines seen below Recommended Run a bead of silicone down these two lines before nailing CPs Nail 6x 40N evenly spaced along CP ...

Page 21: ...il 5 1 ASSEMBLY COVER STRIP ASSEMBLY Hold cover strips CS over joins in walls nail through CS into wall panel using 6x 40N evenly spaced per CS Note Before nailing CS we recommend running a bead of silicone down the joins in the wall as seen below Recommended Run a bead of silicone down joins before nailing CS Nail 6x 40N evenly spaced along CS ...

Page 22: ...ING WALLS TO FLOOR PART CODE QTY DESCRIPTION 65HHS 7 65mm hex head screw 5 2 ASSEMBLY FASTENING WALLS TO FLOOR Ensure walls are in correct position and straight Fasten through wall bottom plate in positions shown below If floor option not chosen fasteners are not supplied ...

Page 23: ...22 P a g e IMAGES TO HELP WITH INSTALLATION FLOOR ...

Page 24: ...23 P a g e ...

Page 25: ...24 P a g e ...

Page 26: ...25 P a g e ...

Page 27: ...26 P a g e ...

Page 28: ...27 P a g e ...

Page 29: ...28 P a g e ...

Page 30: ...29 P a g e ...

Page 31: ...ANTY REGISTRATION FORM YOUR PRODUCT IS NOT COVERED BY WARRANTY PRODUCT MAINTENANCE We highly recommend you coat the external of your product with Intergrain UltraDeck Timber Stain in the Colour Light Oak This product is available from Dulux paint stores or Bunnings stores that have a paint section The product is re tinted from a Cedar Cypress base to achieve the light oak colour Intergrain is a Ca...

Page 32: ...ed in your backyard Please upload this image when completing the warranty registration Alternatively you can send the photos by email to sales stilla com au If you require any assistance please feel free to call or email Kind regards STILLA Customer Support 1800 784 552 sales stilla com au ...

Reviews: