Libretto di Istruzioni 
Instructions Manual 

Manuel d’Instructions 

Bedienungsanleitung 

Manual de instrucciones 

ǽȗȥıțȢȔİțȡ

 

ȡİșȗțȬȟ

 

ɋɮɥɩɝɩɟɬɭɝɩ

 

ɪɩ

 

ɸɥɬɪɦɮɛɭɛɱɣɣ

 

Instrukcja Obs

â

ugi 

Käyttöohje 

 

 
 

Summary of Contents for Lux RB

Page 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Manual de instrucciones ǽȗȥıțȢȔİțȡ ȡİșȗțȬȟ ɋɮɥɩɝɩɟɬɭɝɩ ɪɩ ɸɥɬɪɦɮɛɭɛɱɣɣ Instrukcja Obsâugi Käyttöohje ...

Page 2: ...flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly w...

Page 3: ...y to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowle...

Page 4: ...heavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring thi...

Page 5: ...with Controls Light Fan unit Filters 2 1 Telescopic chimney made up of 2 1 1 Upper chimney 2 2 1 Lower chimney 9 1 Reduction Flange ø 150 120 mm Ref Q ty Installation Components 7 2 1 1 Upper chimney fixing brackets 12a 6 Screws 3 9 x 13 12c 4 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual ...

Page 6: ...rew the hood canopy to the unit from the inside using the screws 12a 3 9 x 13 provided Loosen the screws fixing the spacer and adjust it to the correct position before fastening completely WARNING The Hood Canopy must be fitted into the Unit before it is fixed to the wall DUCTING TO THE REMOTE BLOWER The hood must be ducted to the remote blower using either a flexible or rigid pipe ø 120 mm ...

Page 7: ...EN 1 19 L2 L1 L2 a b L1 L1 L1 L2 L2 L2 L1 L2 a b L1 1 2 3 L2 L1 L2 2 3 L1 1 ...

Page 8: ...r the hood canopy and bring them back together again until they are in contact Fasten the Chimney to the sides of the Hood canopy using 2 Screws 12c 2 9 x 9 5 provided without tightening completely Before tightening the screws it is possible to make slight adjustments to the depth using the chimney slot 12c 2 2 ...

Page 9: ... Speed This speed is timed to run for 6 minutes At the end of this time the system returns automatically to the speed that was set before If it is activated with the motor turned off the hood will switch to OFF at the end of the time Press and hold for 3 seconds to enable the remote control indicated by the LED flashing twice Press and hold for 3 seconds to disable the remote control indicated by ...

Page 10: ... once every 2 months use or more frequently if use is particularly intensive CLEANING THE FILTERS Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Cleaning the Filters Remove the Filter pushing it towards the back of the unit and at the same time pulling downward Wash the filter without bendi...

Page 11: ... at a later date Turn the Lights and the Suction Motor off Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation CHANGING Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Changing the Filter Remove the Metal Grease Filter Remove the saturated Activated charcoal...