11
AFTER SALES SUPPORT
1300 886 649
info@tempo.org
AUS
MODEL: STR-PGGC75 PRODUCT CODE: 10288 09/2019
Important installation advice
Natural gas only:
The cooktop is configured for use with NG (Natural
Gas).
If it is to be used with LPG, it must be converted
using the ULPG (Universal Liquefied Petroleum Gas)
i
njectors provided an
d following the conversion
instructions starting
on page 18. Such a conversion
must only be carried out by a licensed plumber/
gasfitter.
Location:
The cooktop may be located in a kitchen, kitchen/
dining room or a bed-sitting room, but
not
in a room
containing a bath or shower. The cooktop must
not
be installed in a bed-sitting room of less than 20m
3
.
If used with LPG, the cooktop shall not be installed
in a room or space below ground level, such as in a
basement.
Heat resistance of
Wall and bench surfaces must be capable of
surrounding surfaces:
sustaining temperatures of 95°C and be resistant to
heat, steam and condensation. All laminates, fixing
adhesive and surfacing materials must be certified
suitable for this temperature.
We assume no liability for any damage caused if the
appliance is installed contrary to this advice.
Do not install the cooktop near curtains or other
flammable materials.
Ventilation
This appliance must only be used in rooms equipped
requirements:
with adequate ventilation. The use of a gas cooking
appliance results in the production of heat and
moisture in the room in which it is installed. Always
ensure that the kitchen is well ventilated; keep natural
ventilation holes open or install a rangehood.
Prolonged intensive use of the appliance may require
additional or more effective ventilation, for example,
opening of a window or increasing the level of
mechanical ventilation, where present.
Installation (Cont.)