AC BARREL PUMP MOTOR
USER’S MANUAL
F. INSTALLATION
MODEL NUMBER
17004501 & 17004502
Check if the packing was damaged before opening. Make sure no missed spare parts.
Safety Check
Make sure that the supply voltage corresponds to the voltage indicated on the rating plate.
7.1 Motor Installation
1. Pump tube check: Make sure every joint part no looseness. The coupling and shaft could be rotated flexible.
2. Motor Check: Make sure the power cable complete, switch in good condition. Dry running for several minutes to check if the motor
workable. Do not put hands to the motor output shaft.
3. Put the motor coupling is directed at the pump tube. Make sure the pump tube head insert to the motor head completely.
4. The motor and pump tube position could be adjusted by 360°. Put the pump tube adjusted to the suitable position and lock the nut to
finish the installation. It is recommended that the pump exports away from the motor power cable.
7.2 Start
Make sure all the joint parts without leakage. The tube outlet must be fixed well so to avoid pressure leaking.
F7. Electrical Connections
• Terminal strip box complete of:
- ON/OFF switch;
- Speed regulating knob switch
- Speed regulating circuit board
• 5M Power cable
ATTENTION!
IT IS THE INSTALLER’S RESPONSIBILITY TO PREFORM THE ELECTRICAL CONNECTIONS WITH RESPECT FOR THE APPLICABLE
REGULATIONS.
G. DAILY USE
Long time continuous running may cause motor overheating, the overheating protection system will cut the power automatically. The
motor can be restarted work again after cooling down by pressing the on/off button.
ATTENTION!
The suggested duty cycle is 2 hours. Do not exceed one hour when the environment temperature more than 30˚C
Please change the electric brush every 250-300hours
H. NOISE LEVEL
Under normal working conditions the noise emission from all models does not exceed the valve of
80 db at a distance of 1 meter
from
the electric pump.
I. DISPOSING OF CONTAMINATED MATERIALS
In the event of maintenance or demolition of the machine, do not disperse contaminated parts into the environment.
Refer to local regulations for their proper disposal.
E. MOVING AND TRANSPORT
The pump tube and motor adopt the carton box packing. There is enough protection packing material inside. However, never knock on,
heavy load by the non-normal external force. Please transport and stacking as per packing indication. Keep drying and anti-corrosion of
the stacking place.
AC
Switch
M
Speed
regulating
circuit