K: DIAGRAM & PARTS LIST

No.

1

2

3

4

5

6

7

8

No.

9

10

11

12

13

14

15

16

Description

Tapping screw

Speed control knob

Switch block

Head cover

Tapping screw

Rotary knob connector

Toggle switch

Description

 Lining

Speed control circuit board

Motor shell

Tapping screw

The handle cover

Binding post

Wire pressing piece

Cable shield

Qty.

3

1

1

Countersunk head tapping screws2

1

2

1

1

Qty.

1

1

1

3

1

1

1

1

No.

17

18

19

20

21

22

23

24

Description

Motor

Cable

Coupler

Bottom cover 

Flat gasket

Spring washer

Bolt

Tapping screw

Qty.

1

1

1

1

3

3

3

8

3 of 4

AC BARREL PUMP MOTOR 
USER’S MANUAL

MODEL NUMBER

17004501 & 17004502

J. PROBLEMS AND SOLUTIONS

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

No flow rate or small flow rate

Vibration, Big noise

Pump tube leakage

Without opening the electric or air source

Motor failure, do not rotating

Outlet close

Too big pump lift

Too big liquids viscosity

Liquids draining out

The inlet  block off

Liquids draining out

Motor overload

Sliding bearing damage

Coupling wear

Seal ring wear

Circuit failure

Long time working of the motor, overheating 

protection, electric brush damage 

Open the power and air source

Motor Check

Open the outlet valve

Short the transportation distance and height

Check the type with supplier

Stop the pump

Clean the inlet

Stop the pump

Check the liquids viscosity and pump lift

Change the sliding bearing and seal ring

Change the coupling

Change the seal ring

Check the circuit

Restart the motor after cooling down 

Change the electric brush

Reviews: